DEFROST
When the temperature of the copper
tubes is ≤1
o
C, the compressor will
stop after 30 min and the fan will
keep running for defrosting. The
compressor will automatically restart
when the defrost is completed.
Operating instructions
GB
WATER TANK
An indicator will illuminate and a
buzzer will sound 10 times when the
water tank is full. The compressor will
stop automatically which will stop the
unit from dehumidifying.
1. Disconnect the dehumidier from
the power source.
2. Empty the water reservoir.
3. Put the empty reservoir back in its
position.
4. Connect the dehumidier to the
power source.
CLEANING AND MAINTENANCE
To clean the outside of the unit, use
a soft dry cloth. You can use a soft neu-
tral agent if the appliance is very dirty,
but avoid any abrasive tool or liquid.
Do not spray water on the unit. If the
dehumidier is not used for a long
period, unplug the unit, dry the water
container and clean the lter. Store the
unit in a box or cover it to avoid the
dust to build in.
Guarantees
2 years guarantee on the product.
Note that the guarantee is valid only
on production of a receipt.
This machine complies with EEC
directives 76/889 + 82/499
Recommended limits for use
Temperature: +5˚C to +35˚C
Relative humidity: 0% to 80%
Recommended
humidity level: appr. 50% RH
DRAINAGE OF WATER
The dehumidier is tted with a hose
connection: please refer to FIG 8 and
FIG 9.
Using the hose:
1. Disconnect the dehumidier from
the power source and remove the
water reservoir to give access to the
drip tray.
2. Attach the hose coupling to the
thread on the dehumidier and lead
the hose to a drainage outlet. Check
that the hose is not above the level of
the drip tray.
3. Connect the dehumidier to the
power source.
WHEN THE DEHUMIDIFIER
REQUIES SERVICING
If the dehumidier requires servicing,
you must rst contact the retailer.
Proof of purchase is required for all
warranty claims.
LOW TEMP. MODE
When the ambient temperature is
≤5˚C, the product will nish its defrost
cycle one time, and then, the compres-
sor keeps working for 30 min and the
fan keeps working for 70 min. After
this time, the fan will run for 1 min,
every 30 minutes. When the ambient
temperature has been ≥7
o
C for at least
7 minutes, the unit will restart opera-
tion at the last set mode.
NOTE :
Always disconnect the cord
before cleaning.
NOTE :
If the supply cord is damaged, it
must be replaced by the manufac-
turer, its service agent or similarly
qualied persons in order to avoid
hazard.
THE AIR FILTER
The air lter at the rear of the
dehumidier ensures that the cool-
ing coils are kept free of dust. It is
important that the lter is kept clean
so that air can ow freely through the
dehumidier. The lter should thus be
cleaned when required.
1. Remove the lter
2. Wash it with warm water and a mild
cleansing agent. Alternatively the lter
may be vacuum cleaned.
3. Let the lter dry and put it back.
HINTS:
- When the dehumidier is used in
extremely damp environments or when the
temperature is below +10˚C, the dehumidi-
er may stop working. A large amount of
ice builds up on the cooling coil. Turn o
the dehumidier and place it a little above
oor level so that the ice
will melt away.
- For maximum dehumidifying power in a
room, it is recommended that the air sup-
ply from outside and from adjoining rooms
is minimized – close doors and ventilators.
- Increase temp. for faster dehumidication
( warm air carries more water.)
- Higher dehumidication in Autumn /
Summer because outside air is warm and
humid.
- If the power is stopped suddenly, the
machine will remain shut o for 3 minutes
before restarting automatically when the
power returns.
- When the desired humidity is reached
the compressor will shut o and the fan
continues to work for 5 min and before
shutting o for 1h. This cycle is repeated
until the humidity level rises. The compres-
sor and fan then returns to operate as
normal
IMPORTANT :
Wood’s dehumidiers must be
connected to an earthed power
source. (200-240V, 50 Hz)
04