Shutdown
9
Greenstar 8000 Life – 6720883872 (2019/02)
5.2 Key LED
Key LED status
The LED [1] on the Key displays different states with flashing or constant
colours.
Table 5 LED status
6 Shutdown
6.1 Setting frost protection
NOTICE:
Risk of damage to the system from frost!
The heating system can freeze up after a prolonged period (e.g. during a
power failure, switching off the power supply, faulty fuel supply, boiler
fault etc.).
Ensure that the heating system is in constant use (particularly when
there is a risk of frost).
If you are leaving your property unoccupied during cold weather, please
leave your external programmer on constant and your room thermostat
set to 12 °C.
7 Clearances and ventilation information
7.1 Appliance clearances
Your installer will have provided adequate space around the appliance
for operation, safety and servicing/maintenance access.
The following detail the necessary clearance around the appliance for
service and maintenance.
CAUTION:
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 9 Appliance minimum clearances
Table 6
[*] Height for either 60/100 flue or 80/125 flue
7.2 Ventilation information
The air supply must not be restricted or contaminated.
Ventilation considerations
Do not place objects to hinder the air circulation required by the
appliance.
The installation premises may require ventilation to be fitted
according to its features or use.
Description of the LED displays Example
Flashing red:
Fault, e.g. no communication between the Key and
appliance:
Install the key again, restore the last functioning status.
Flashing yellow:
No fault, user please wait.
Flashing green:
No fault, initialisation process is running.
Constant red:
Temporary fault:
Wait for normal operating condition to be resumed.
Constant yellow:
No fault, time and date not available:
Set the time and date on the appliance.
-or-
Keys with button: Press button on key to start pairing.
Constant green:
No fault, normal operating condition.
LED Off:
No fault, power-saving mode or appliance without power.
Minimum clearances
Description Dimensions (mm)
X Appliance width 440
Y Appliance height 780
Z Appliance depth 365
Installation/Maintenance
1 Overall clearance height 1,150/1,190 *
2 Overall clearance depth 965
3 In front of appliance 600
4 Overall clearance width 450
5 Above the appliance 170/210 *
6 Either side of appliance 5
7 Below the appliance 200
8 Compartment depth 385
9 Appliance to removable door 20
0010012940-001