Typical Values for Peukert's Exponent "n"
This table contains values for the exponent "n" for various batteries and
manufacturers. They are calculated from the 20-hour rating and the
Reserve Minutes @ 25 A as supplied by the manufacturer. They should be
considered only a guide for selecting "n."
Prevailer & SeaGel Batteries
Model Volts Res. Min. 20-Hr. rating "n"
8GGC 6 375 180 1.14
8GU1 12 43 43 1.20
8GU24 12 130 70 1.13
8GU27 12 167 86 1.12
8GU30H 12 188 95 1.12
84D 12 388 180 1.11
8G8D 12 500 225 1.10
Trojan Batteries
Model Volts Res. Min. 20-Hr. rating "n"
T-105 6 447 225 1.24
T-125 6 488 235 1.19
T-145 6 530 244 1.14
J250 6 535 250 1.17
J305 6 660 305 1.21
L16 6 760 350 1.28
24TM 12 135 85 1.23
27TM 12 160 105 1.28
30XHS 12 225 130 1.27
SCS225 12 225 130 1.27
EV8D 12 450 216 1.17
Peukert's Equation
Peukert's Exponent