Troubleshooting
Problem Suggestion
No lights or display Check Power Connections
Reset meter (page 28)
No keyboard response Check Lock is not invoked
Reset meter (page 28)
Time Remaining Not Check Battery Capacity (page 21)
Accurate Check Temperature Coefficient (page 32)
Check Peukert Exponent (page 26)
Digital Display Dim Clean front panel photo-sensor
(Between A and Ah lights)
Current Polarity Reversed Current Shunt leads reversed (page 13)
Intermittent Operation Corrosion or loose wires. Loosen and
reconnect all rear panel connections.
Check voltage sense and shunt wiring
at battery location.
Accumulates Negative Charge Parameters not met. Check
Amp-hour reading Charged Parameter values—has 100% of
kWh been returned? Charging Current is
not passing through shunt (pages 13, 22,
23, and Function F04).
Xantrex Technology, Inc. warrants that the Link 10 will measure voltage,
amperage, and amp hours within the published specifications. The Time
Remaining and LED bar graph functions are complicated and require
appropriate user setup and are therefore beyond the control of Xantrex
and are not covered by warranty. Similarly, installation wiring and specific
applications are beyond our control and are not covered by warranty.