© 2001 Xantrex Technology Inc. 29
P/N 973-0012-01-02 Rev. A 05/01
Indicators and Controls (continued)
To access the Data Monitor Function:
Press and hold the SELECT button until dSF appears in the LED display.
The display alternates between the data monitor function and its data.
Press the RESET button to display the value for the selected function.
Continue pressing the SELECT button to scroll through all the available
displays and their data.
When the “bLO” data has been accessed, another press of the SELECT
button returns to the basic meters function.
To reset the data monitor values to zero (or the present value) press and
hold the RESET button for approximately 5 seconds (the data monitor value
flashes three times and then updates).