EasyManua.ls Logo

Xantrex Trace TM500A - 1.0 INTRODUCTION; The TM500 A; Unpacking and Inspection

Xantrex Trace TM500A
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
© 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01
The TM500A
The TM500A features six data monitoring functions and three indicators
including:
State of charge/amp-hour content (full or percent of capacity)
State of charge/voltage (real-time voltage level, historical high and low
system voltage)
Amps (real-time amps, total charging amps, total load amps)
Amp hours removed
Days since fully charged
Cumulative amp hours
Recharge indicator
Low-voltage indicator
Full-charge indicator
The unit is configurable for specific system or application functions such
as setting the CHARGED indication parameters, battery capacity, charging
efficiency, low-battery warning conditions and a recharge reminder. The
TM500A can monitor any battery supply from approximately 8 to 65 volts,
track energy consumption and estimate remaining battery life.
In addition to its status monitoring features, the unit can act as a remote
control, switching the inverter OFF or ON (only on inverters incorporating an
RC4/RC8 compatible remote control jack).
The TM500A operates on 12-, 24-, or 48-volt battery systems (48-volt
systems require an optional shunt board).
Figure 1-1
The TM500A
14.2
1.0 INTRODUCTION

Related product manuals