Do you have a question about the Xantrex XHR 600-1.7 and is the answer not in the manual?
Model | XHR 600-1.7 |
---|---|
Output Power | 600 W |
Efficiency | 90% |
Operating Temperature | 0 to 50°C |
Safety Standards | UL, CE |
Input Voltage | 90 - 265 VAC |
Cooling | Fan Cooled |
Storage Temperature | -20°C to +85°C |
Humidity | 0-95% non-condensing |
Details the scope of the warranty and its specific time period.
Explains Xantrex's responsibilities for repairing or replacing defective products.
Provides contact information and procedures for initiating warranty service.
Lists conditions and damages not covered by the limited warranty.
Key safety warnings and precautions for operating the power supply.
Identifies the intended user and their required technical background.
Lists the different versions and release dates of the manual.
Provides a general overview of the 1000 Watt DC output power supplies.
Details the product's available features and optional configurations.
Details the function and configuration of the SW1 switch.
Describes the connections and functions of the J2 connector.
Lists detailed electrical performance parameters.
Outlines operating and storage conditions for the unit.
Provides physical dimensions and construction details.
Step-by-step guide for initial setup and connection.
Process for obtaining authorization and returning faulty units.
Verifies basic power-up functionality and initial status.
Tests voltage output behavior and control.
Guidelines for connecting loads to the power supply.
Information on wire gauge selection based on current limits.
Details on connecting loads to the front panel binding posts.
Recommended connections for a single load setup.
Methods for connecting multiple loads to the supply.
Basic operating principles and modes of the power supply.
Explanation of Constant Voltage/Current modes and transitions.
Describes the factory default settings for front panel operation.
Procedure for setting the output voltage and current limit.
How to use and set OVP parameters via the front panel.
Procedures for resetting the over voltage protection circuit.
Operation of the front panel standby switch to control output.
Remote activation of the shutdown function using the J2 connector.
Immediate safety procedures to follow in an emergency.
Basic steps for diagnosing and resolving operational issues.
How to control the supply remotely via analog signals.
Details on available programming scales (voltage/resistance).
Accessing output status remotely via readback signals.
How to set up and use the ISOL interface for isolated control.
General preparation and safety precautions for calibration.
Lists the necessary tools and equipment for calibration.
Procedure to calibrate the front panel voltmeter display.
Procedure to calibrate the front panel ammeter display.
Calibrating the remote voltage programming circuit for accuracy.
Calibrating the remote current programming circuit for accuracy.
Calibrating the voltage monitor circuit for accurate readback.
Calibrating the current monitor circuit for accurate readback.