Output Current | 0-18 A |
---|---|
Output Power | 1080 W |
Frequency | 47-63 Hz |
Voltage Resolution | 10 mV |
Current Resolution | 10 mA |
Efficiency | >85% |
Current Accuracy | 0.1% + 10 mA |
Ripple and Noise | < 10 mVrms |
Operating Temperature | 0 to +50°C |
Storage Temperature | -20 to +70°C |
Output Voltage | 0 - 60 VDC |
Details the scope and length of warranty coverage for the XHR 1000 Watt Series DC Power Supply.
Explains Xantrex's commitment to repair or replace defective products under warranty terms.
Provides contact details and procedures for customers seeking warranty service or technical support.
Lists specific conditions, damages, or uses that are not covered by the limited warranty.
States that federal law may limit warranty exclusions, and consumer rights may vary by jurisdiction.
Advises against using the power supply with life support systems and clarifies warranty limitations for such applications.
Outlines safety definitions and precautions for operating the power supply, including high voltage warnings.
Warns about the presence of high energy levels and potentially lethal voltages within the power supply unit.
Provides essential safety measures and recommendations when using the power supply for battery charging applications.
Identifies the intended user and outlines the manual's coverage of power supply operation and features.
Lists the current release of the manual and notes the possibility of future updates or addenda.
Covers the power supply's description, features, options, and front panel controls.
Details rear panel connectors, SW1 switch, J2 connector, and wiring considerations.
Presents electrical, environmental, and mechanical specifications, including input conditions and approvals.
Covers remote programming, monitoring capabilities, environmental limits, and mechanical design.
Outlines basic setup steps, inspection, cleaning, packing, and return procedures.
Covers rack mounting, ventilation, and AC input power connection requirements.
Details procedures for functional testing and connecting loads to the power supply.
Provides recommendations for load wiring, current capacity, and using local/remote sensing.
Covers standard modes, crossover, shipped configuration, and setting voltage/current limits.
Details series, parallel, and split supply configurations for increased voltage or current output.
Explains Over Voltage Protection (OVP), Shutdown Function, and Over Temperature Protection (OTP).
Provides troubleshooting steps, emergency shutdown, and checks for unusual operation.
Covers remote analog programming, options, and the ISOL interface for voltage and current control.
Provides step-by-step instructions for setting up remote analog programming using switches and J2 connector.
Explains how to monitor output voltage and current using rear panel signals and SW1 settings.
Details the ISOL interface, its specifications, setup, and operating instructions.
Covers setup, safety precautions, and required equipment for performing calibration.
Details calibration of voltmeter, ammeter, and OVP functions using front panel controls and internal adjustments.
Explains how to calibrate voltage and current programming circuits for accuracy.
Details calibration of voltage and current monitor circuits for accurate readback signals.