Caution
Drums are light sensitive. Do not leave the Drum Cartridge Drawer open for more
than one minute when replacing cartridges. Exposing the drum cartridges to direct
sunlight or strong light from indoor fluorescent lighting for more than one minute
may cause image quality defects.
8. Install the new drum cartridge into the press following the guides with the side marked
front facing the front.
9. Press both ends of the drum cartridge to place it in a horizontal position.
10. Immediately close the drum cartridge drawer to protect the other drums from light.
11. Return the Release Handle to its original position.
12. Return the R1-R4 handle to the original position and close the front door / cover.
13. Insert the used drum cartridge into an empty container for recycling.
Replacing the Suction Filter
You will need the T10 Torx driver tool for this procedure.
After you replace the filter, you will need to contact the system administrator who will
log into administrator mode and reset the High Frequency Service Item (HFSI) counter
for this CRU to zero (0).
Caution
Make sure the press is powered off before performing this procedure.
1. At the back of the press, locate the Suction filter cover on the lower panel.