EasyManua.ls Logo

Xinje ZG3 Series - High-Speed Counting and CAM Registers

Xinje ZG3 Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
……
……
SFD73*
I77 corresponds to
X**
Default value is 77Octonary
O Mapping
ID
Function
Description
SFD74*
O00 corresponds to Y**
Output terminal 0 correspond to
Y** number
0xFF means terminal bad
0xFE means terminal idle
Default value is 0
……
……
SFD134
*
O77 corresponds to Y**
Default value is 77Octonary
I Attribute
ID
Function
Description
SFD138*
I00 attribute
Attribute of input terminal 0
0positive logic
others negative
logic
SFD139*
I01 attribute
……
……
SFD201*
I77 attribute
High Speed Counting
ID
Function
Description
SFD320
HSC0 frequency times
2 2 times frequency 4: 4 times
frequency(effective at AB phase counting mode)
SFD321
HSC2 frequency times
Ditto
SFD322
HSC4 frequency times
Ditto
SFD323
HSC6 frequency times
Ditto
SFD324
HSC8 frequency times
Ditto
SFD325
HSC10 frequency times
Ditto
SFD326
HSC12 frequency times
Ditto
SFD327
HSC14 frequency times
Ditto
SFD328
HSC16 frequency times
Ditto
SFD329
HSC18 frequency times
Ditto
SFD330
Bit selection of HSC absolute
and relative24 segment
bit0 corresponds to HSC0 bit1corresponds to
HSC2and so on, bit9 corresponds to HSC18
0relative
1absolute
SFD331
Interrupt circulating of 24
segments high speed counting
bit0 corresponds to HSC0 bit1corresponds to
HSC2and so on, bit9 corresponds to HSC18
0single

Related product manuals