EasyManua.ls Logo

Xinje ZG3 Series - Page 66

Xinje ZG3 Series
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SFD1160
Pulse parameters setting
Bit 0logic of pulse output
0positive logic;
1negative logic , default is 0
Bit 1logic of pulse direction
0positive logic;
1negative logic , default is 0
Bit 8pulse unit
0pulse number;
1pulse equivalent, default is 0
Public
parameters
PULS
E_3
SFD1161
SFD1162
Low 16 bits of pulse number per
circle
SFD1163
High 16 bits of pulse number per
circle
SFD1164
Low 16 bits of pulse equivalent
per circle
SFD1165
High 16 bits of pulse equivalent
per circle
SFD1166
Pulse direction terminal
Assign the number of termimal Y,
0xFF for no terminal
SFD1167
Direction delay time
Default 20unitms
SFD1168
Positive compensation of gear
gap
Negative compensation will also
use this data when gear gap
negative compensation =0
SFD1169
Negative compensation of gear
gap
SFD1170
Low 16 bits of Electrical origin
position
SFD1171
High 16 bits of Electrical origin
position
SFD1172
Mechanical back to origin
parameter setting
Bit0Switch state setting of near
point, 0 Normally ON
1Normally OFF
SFD1173
Terminal setting of near point
signal
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD1174
Z phase terminal setting
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD1175
Limit terminal setting
Bit7~bit0Assign limit 1 number
of terminal X, 0Xff for not
terminal
Bit15~bit8 Assign limit 2
number of terminal X, 0Xff for
not terminal

Related product manuals