EasyManua.ls Logo

XSY AT2 - Advanced, PID, and Protection Parameters

Default Icon
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P57
Multifunctioninput1
0:invalid,nooutput;
1:operatinginstructions;
2:setarrivalinstructions
3:faultindication;
4:timertimerunout
0
P58
Multifunctioninput2 Idem (SP1)
0
P59
Multifunctioninput3 Idem
0
P60
Multifunctioninput4 Idem (relayoutput)
0
P61
PIDoptions
0:invalid;
1:positiveinputnegativefeedback;
2:negativeinputnegativefeedback;
3:positiveinputpositivefeedback;
4:negativeinputpositivefeedback.
0:settingfrequency;
1
:
operating
frequency
;
14
P62 Displayoptions
1
:
operating
frequency
;
2:revolution3:current;
4:temperature;5:time;
0
P65
Poweronoptions
0:normalpoweron;
1:reporterrorwithstartsignalwhen
poweron;
2:Poweronforward;
3:Poweronreverse.
0
P66
Input stabilization time
0---65535
60 mS
P67
Voltage coefficient
0---65535
3250
0
P68
Under voltage setting
0---220.0
160 V
P69
Overvoltage setting
220.0---400.0
300 V