XTM40 Technical data
23
11 Technical data
I
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
XTM40
Connection voltage: 12/24 Vg and 100 – 240 Vw
Rated current
– 12 Vg:6.0 A
– 24 Vg:3.0 A
– 100–240Vw: 1.3 A to 0.7 A
Cooling capacity: +10 °C to –18 °C (+50 °F to 0 °F)
Gross volume: 39 l
Storage volume: 37 l
Climate class: N or T
Ambient temperature: 18 °C to 43 °C (+50 °F to 109.4 °F)
Noise emission: 45 dB(A)
Refrigerant quantity:
4
5 g
CO
2
equivalent: 0.059 t
Global warming potential (GWP): 1430
Dimensions (L x W x H) in mm
(with handles removed):
580 x 360 x 462
Dimensions (L x W x H) in mm
(including handles):
638 x 360 x 462
Weight: 16.7 kg
Test/certificates:
NOTE
If the ambient temperature is above 32 °C (90 °F), the minimum
temperature cannot be attained.
XTM40-O-AUS.book Seite 23 Montag, 7. Januar 2019 2:30 14