4
CAUTION: This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if
they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Voltage Input 100-240 VAC
Cycles 50/60 Hz
Current 1.2 Amps Max.
Maximum Pressure 40 PSI (2.8 Bar) Max.
Accumulator Air Tank Pressure 18 PSI (1.2 Bar)
Housing Material ABS
Shipping Weight 4.6 lb. (2.1 kg)
Wet Weight 7.5 lb (3.4 kg)
Overall Dimensions
11.5 in L x 10.5 in W x 7.1 in H
292 mm x 267 mm x 181 mm
Fluid Outlet 3/8” (9.5mm) OD Push-in Tube
Specifications
Application Notes & Troubleshooting
System will not dispense fluid
• Check ON/OFF switch position
• Check power to dispensing system
• Check tubing and fluid connections
• Check for empty fluid container
• Check power cable is fully inserted and switched on at the mains
System will not shut-off
• Check for leaks in tubing system
• Check for air in system, purge air
Low flow or system continually turns on and off
• Check accumulator air pressure
1. Wear appropriate safety gear
2. Turn off power and relieve water pressure
3. Unscrew valve cap and adjust air pressure to 18 PSI (1.2 Bar)