Installation, Operation, and
Maintenance Manual
90016001_2.0
Flygt 3102

Table of Contents

Questions and Answers

  • B
    bscottAug 5, 2025
    How to fix signs of wear on the impeller, pump, and casing of Xylem Water Pump?
    • J
      Jesse WalkerAug 6, 2025
      Replace the worn parts of the Xylem Water Pump.
  • M
    madeline78Aug 9, 2025
    What to do if the Xylem Flygt 3102.190 runs but the motor protection trips?
    • S
      Stephen JonesAug 9, 2025
      If the Xylem Water Pump runs, but the motor protection trips, it could be due to several reasons. First, the motor protection might be set too low; in this case, adjust the motor protection according to the data plate and cable chart. Alternatively, the impeller might be difficult to rotate; clean the impeller, clear out the sump, and ensure the impeller is properly trimmed. Also, check the fuses and replace any that have tripped. If the fuses are intact, then notify a certified electrician.
  • R
    Randy ShieldsAug 13, 2025
    Why does my Xylem Flygt 3102.190 deliver too little or no water?
    • A
      Adam JenkinsAug 14, 2025
      If your Xylem Water Pump delivers too little or no water, several factors could be at play. Ensure the impeller is rotating in the correct direction; if it's a 3-phase pump, transpose two phase leads. Check that all valves are set correctly and replace them if necessary, ensuring they are installed according to media flow and open correctly. Additionally, inspect for obstructions in the pipes and clean them to ensure free flow. Finally, check for leaks in the pipes and joints and seal them.
  • L
    Lee LewisAug 18, 2025
    What to do if Xylem Water Pump starts-stops-starts in rapid sequence?
    • S
      Sonya RogersAug 18, 2025
      If the Xylem Water Pump starts and stops rapidly, it might be due to back-flow filling the sump to the start level again. Ensure the distance between the start and stop levels is sufficient and that the non-return valves are working correctly. Also, check that the length of the discharge pipe between the pump and the first non-return valve is sufficiently short. Another potential cause is a malfunction in the self-holding function of the contactor. Inspect the contactor connections, the voltage in the control circuit, the functioning of the stop-level regulator, and whether the voltage drop in the line at the starting surge causes the contactor's self-holding malfunction.
  • A
    Adrian MyersAug 22, 2025
    How to troubleshoot if Xylem Flygt 3102.190 Water Pump does not start?
    • S
      simpsonerinAug 23, 2025
      If the Xylem Water Pump does not start, it could be due to an alarm signal triggered on the control panel. Check that the impeller rotates freely, the sensor indicators do not indicate an alarm, and the overload protection is not tripped. If the pump does not start automatically but can be started manually, verify that the start level regulator is functioning (clean or replace if necessary), all connections are intact, the relay and contactor coils are intact, and the control switch (Man/Auto) makes contact in both positions. Also, check the control circuit and functions.
  • M
    Meagan MooreAug 27, 2025
    What to do if Xylem Flygt 3102.190 Water Pump does not stop when a level sensor is used?
    • C
      Christopher MonroeAug 27, 2025
      If the Xylem Water Pump doesn't stop when a level sensor is used, it might be because the pump can't empty the sump to the stop level. Check for leaks in the piping or discharge connection, ensure the impeller isn't clogged, and verify the non-return valves are functioning properly. Also, make sure the pump has adequate capacity. Another reason could be a malfunction in the level-sensing equipment; clean the level regulators, check their functioning, check the contactor and the control circuit, and replace any defective items. Lastly, the stop level might be set too low, so raise it.
  • C
    Craig CarneyAug 31, 2025
    What to do if the liquid level is too low in Xylem Flygt 3102.190 Water Pump?
    • G
      Gina HammondAug 31, 2025
      • Check that the level sensor is set correctly. • Depending on the installation type, add a means for priming the Xylem Water Pump, such as a foot valve.

Summary

Product Description

Product Approvals and Denomination

Product certifications for hazardous locations and code structure.

Installation

Installation Precautions and Hazardous Atmospheres

General safety warnings and rules for hazardous environments.

Electrical Connections

Guidance on making electrical connections, grounding, and cable preparation.

Operation

Zinc Anode Replacement and Pump Startup

Estimating anode replacement and procedures for starting the pump.

Maintenance

Troubleshooting

Electrical Troubleshooting

Guidelines for safely troubleshooting electrical issues.

Pump Start-Up Issues

Diagnosing why the pump fails to start or stops prematurely.

Performance Issues

Troubleshooting motor protection trips and low/no water delivery.

Xylem Flygt 3102.190 Specifications

General IconGeneral
TypeSubmersible Pump
InstallationSubmersible
Frequency50 Hz
MaterialCast Iron
Protection ClassIP68
Insulation ClassF
Outlet ConnectionDN 80
ApplicationWastewater
Voltage400 V