EasyManuals Logo

Xylem Flygt 3102.190 User Manual

Xylem Flygt 3102.190
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
8 Technical Reference
8.1 Application limits
Data Description
Liquid temperature 40°C (104°F) maximum
The pump can be operated at full load only if at least half
the stator housing is submerged.
3102.060, 3102.160, 3102.181, 3102.760:
Warm-liquid version: 70°C (158°F) maximum
pH of the pumped media (liquid) 5.5–14
Liquid density 1100 kg/m³ (9.2 lb per US gal) maximum
Depth of immersion Maximum 20 m (65 ft)
Other For the specific weight, current, voltage, power ratings,
and speed of the pump, see the data plate of the pump.
8.2 Motor data
Feature Description
Motor type 3102.060/.070/.090/.160/.170/.181/.190/.760/.770/.890:
Squirrel-cage induction motor
3102.900/.910/.920/.930/.960/.970:
Line-started, permanent-magnet synchronous motor
Frequency 50 Hz or 60 Hz
Supply 1-phase or 3-phase
Starting method Direct on-line
Star-delta
Soft starter
Not recommended for LSPM motors
Variable Frequency Drive (VFD)
Maximum starts per hour 30 evenly-spaced starts per hour
Code compliance IEC 60034-1
Voltage variation without
overheating
±10%, if it does not run continuously at full load
Voltage imbalance
tolerance
2%
Stator insulation class H (180°C [356°F])
Motor encapsulation
Motor encapsulation is in accordance with IP68.
8 Technical Reference
Flygt 3102 Installation, Operation, and Maintenance Manual 71

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Flygt 3102.190 and is the answer not in the manual?

Xylem Flygt 3102.190 Specifications

General IconGeneral
BrandXylem
ModelFlygt 3102.190
CategoryWater Pump
LanguageEnglish

Related product manuals