Model HSC
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTRUCTION MANUAL
IM008
Question and Answer IconNeed help?

Do you have a question about the Xylem Goulds HSC20 and is the answer not in the manual?

Xylem Goulds HSC20 Specifications

General IconGeneral
ModelHSC20
TypeCentrifugal Pump
Power SourceElectric
Phase3
MaterialCast Iron
Suction Size2 inch

Summary

Safety and General Instructions

Important Safety Checks

Inspect unit for damage and report any damage to carrier/dealer immediately.

Electrical Supply and Motor Safety

Ensure proper electrical supply, wiring, and motor protection as per codes and manual guidelines.

Operating and Installation Limits

Adhere to maximum liquid temperature, pressure, starts per hour, and installation guidelines.

Installation Best Practices

Guidelines for pump placement, ventilation, piping support, fitting selection, and orientation.

Critical Installation Caution

Never draw piping into place by forcing connections; do not install motor below pump.

System Installation and Operation

Foundation and Piping Installation

Proper foundation, casing bolt tightening, suction/discharge piping setup, and rotation check.

Suction Piping Guidelines

Ensure low static lift, direct piping, proper pipe size, and avoid air pockets for efficient suction.

Discharge Piping Setup

Include check and gate valves, use Teflon tape for threaded connections, and consider increasers.

Pump Operation and Priming

Prime pump before starting, keep discharge valve partially open, and check system after stabilization.

Maintenance and Pump Dry Run Warning

Bearings are permanently lubricated. Do not run pump dry; it will cause seizing and damage.

Pump Disassembly, Reassembly, and Troubleshooting

Disassembly Procedures

Step-by-step guide for disassembling the pump, including mechanical seal and impeller removal.

Reassembly Best Practices

Clean parts, inspect components, lubricate o-rings, and reassemble carefully following guidelines.

Troubleshooting Common Issues

Lists common problems like motor not running, low delivery, noise, and vibration with probable causes.

Parts List and Diagram

Component Identification

Detailed list of all pump components with item numbers, names, quantities, and motor codes.

Exploded Assembly Diagram

Visual representation of pump components and their arrangement, referenced by item numbers.

Warranty Information

Warranty Coverage Details

Covers defective parts for 12 months from installation or 18 months from manufacture, whichever is shorter.

Warranty Exclusions and Limitations

Excludes labor, transportation, reinstallation costs, consequential damages, and loss from service interruption.

Warranty Terms Definitions

Defines 'Distributor', 'Dealer', and 'Customer' for the purpose of warranty claims.