Do you have a question about the Xylem Goulds HSC20 and is the answer not in the manual?
| Model | HSC20 |
|---|---|
| Type | Centrifugal Pump |
| Power Source | Electric |
| Phase | 3 |
| Material | Cast Iron |
| Suction Size | 2 inch |
Inspect unit for damage and report any damage to carrier/dealer immediately.
Ensure proper electrical supply, wiring, and motor protection as per codes and manual guidelines.
Adhere to maximum liquid temperature, pressure, starts per hour, and installation guidelines.
Guidelines for pump placement, ventilation, piping support, fitting selection, and orientation.
Never draw piping into place by forcing connections; do not install motor below pump.
Proper foundation, casing bolt tightening, suction/discharge piping setup, and rotation check.
Ensure low static lift, direct piping, proper pipe size, and avoid air pockets for efficient suction.
Include check and gate valves, use Teflon tape for threaded connections, and consider increasers.
Prime pump before starting, keep discharge valve partially open, and check system after stabilization.
Bearings are permanently lubricated. Do not run pump dry; it will cause seizing and damage.
Step-by-step guide for disassembling the pump, including mechanical seal and impeller removal.
Clean parts, inspect components, lubricate o-rings, and reassemble carefully following guidelines.
Lists common problems like motor not running, low delivery, noise, and vibration with probable causes.
Detailed list of all pump components with item numbers, names, quantities, and motor codes.
Visual representation of pump components and their arrangement, referenced by item numbers.
Covers defective parts for 12 months from installation or 18 months from manufacture, whichever is shorter.
Excludes labor, transportation, reinstallation costs, consequential damages, and loss from service interruption.
Defines 'Distributor', 'Dealer', and 'Customer' for the purpose of warranty claims.