4" Submersible Pumps
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTRUCTION MANUAL
IM116R09
SERIES

Questions and Answers:

Xylem Goulds Red Jacket Series Specifications

General IconGeneral
BrandXylem
ModelGoulds Red Jacket Series
CategoryWater Pump
LanguageEnglish

Summary

SAFETY INSTRUCTIONS

TYPICAL INSTALLATIONS

Captive Air Tank Installation

Illustrates typical installations for captive air tanks and notes about pre-charge.

Galvanized Tank Installation

Depicts typical installations for galvanized tanks, including drain fitting settings.

PIPING AND SYSTEM COMPONENTS

General Piping Guidelines

Discusses pump discharge piping sizing, friction loss, and pipe material recommendations.

Pressure Tank, Switch, and Relief Valve

Covers selection of location, installation, and switch placement for tanks, switches, and relief valves.

Adjusting Tank Pre-Charge

Explains how to check and set the tank pre-charge pressure relative to the pump cut-in pressure.

Pump Installation Procedures

Pump Assembly and Well Installation

Details connecting the pump end to the motor and installing the pump assembly into the well.

Special Piping and Check Valves

Covers special piping for galvanized tanks, air escape, and the function/installation of check valves.

WIRE SIZING AND SPLICING

Splicing Wire to Motor Leads

Provides detailed instructions for making watertight splices using heat shrink kits or waterproof tape.

WIRING CONTROLS AND SWITCHES

Control Box Mounting and Power Verification

Guides on mounting the control box, verifying voltage, and ensuring power is OFF before wiring.

Connecting Motor Leads and Power Supply

Details connecting motor leads for single/three-phase motors and making final power supply connections.

THREE-PHASE POWER MANAGEMENT

Overload Protection and Power Unbalance

Covers Class 10 overload protection and calculating/correcting three-phase power unbalance.

STARTING THE PUMP

Initial Startup and Water Clearing

Describes flushing the well and pump during initial startup using a valve to clear water.

Preventing Upthrust Damage

Advises on using flow restrictors or valves to prevent upthrust damage in wells with high static levels.

PAPERWORK AND IOM

TECHNICAL DATA

Motor Insulation Resistance Readings

Provides guidance on performing motor insulation resistance tests and expected Ohm/Megohm values.

Generator Operation Requirements

Offers safety warnings and minimum generator rating requirements for operating pumps with generators.

WIRING DIAGRAMS

Two-Wire Direct Connection Diagram

Illustrates the wiring diagram for a two-wire pump directly connected to a pressure switch.

Three-Wire Direct Connection Diagram

Shows the wiring diagram for a three-wire pump connected directly to a pressure switch.

THREE-PHASE WIRING DIAGRAMS

Three-Wire with Magnetic Contactor Diagram

Displays the wiring diagram for a three-wire pump using a magnetic contactor.

Three-Phase Magnetic Starter Diagram

Presents the wiring diagram for three-phase connections using a magnetic starter with quick-trip heaters.