9
WARNING
ELECTRICALLYGROUNDBLOWER.
CONNECTGROUNDWIRETOGREENANDYELLOW
GROUNDWIREINTERMINALBOX.FAILURETODOSOCAN
RESULTINDEATHORELECTRICALSHOCK.
7 Connectgreen(orbare)groundwirefromhomepower
supplytoyellow-greengroundwire(F)interminalboxusingUL
listed wire connectors.
8 Tighten strain relief screw.
9 Install terminal box cover.
10 Check that all light bulbs are secure in their sockets.
11 Reconnect power.
Install duct covers
• When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and install
with two mounting screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
C
A
B
C
D
A.Upperventcover
B. Lower vent cover
C. 4 x 8 mm screws
D. Bracket
Complete Installation
• Fornon-vented(recirculating)installationsonly,installcharcoal
ltersovermetalgreaselter.Seethe“Mainteinance”section.
• Installmetallters.Seethe“Mainteinance”section.
Togetthemostefcientusefromyournewrangehood,readthe
“Maintenance”section.
KeepyourUse,Care,andinstallationGuideclosetorangehood
for easy reference.
Description of the Hood
5
1
4
2
3
1. Blower and light controls
2. LED lamps
3. Grease filter handle
4. Grease filter
5. Duct covers