25
4
Wrong Code
Entry Limit
1 byte
0x03
0x0A
0x03
Adjust the limit for
wrong code entries
allowed by your lock.
61
7
Shut down time
1 byte
0x0A (10
seconds)
0x84 (132
seconds)
0x3C (60
seconds)
Adjust the time your
lock is shutdown after
reaching its wrong code
entry limit.
80
8
Operating mode²
1 byte
0x00
(Normal
Mode)
0x03
(Passage
Mode)
[0x8104]
0x00
(Normal
Mode)
Set the Operating Mode
to normal mode, keypad
disable mode or
passage mode.
76
11
One Touch
Locking
1 byte
0x00
(Disable)
0xFF
(Enable)
0xFF
(Enable)
Set One Touch Locking
feature to enable or
disable.
51
13
Lock Status LED
1 byte
0x00
(Disable)
0xFF
(Enable)
0x00
(Disable)
Set Lock Status LED
feature to enable or
disable.
49