2. Product explanation
17
GB
(2) Controls and Equipment
Key Switch
Rotary switch with 4 positions.
In the OFF position, the switch key can be inserted or removed.
In OFF, all electric current is cut off.
In ON (1 position to the right), the engine is turned on.
In ON, electric current to the controls and equipment is turned
on.
In the START position the engine will start.
The engine cannot be stopped with the key switch.
In GLOW, position for turning on the air heater.
The air heater Option aids starting during cold conditions by
warming up the intake air before starting.
Note:
Neutral Safety Switch
The engine can only be started when the clutch is in neutral. If an
attempt is made to start the engine in any other position, the
neutral safety switch will operate to make starting impossible.
(3) Alarm Equipment (lamps and buzzer)
Mechanism
When the sensor detects a problem during
operation, the lamps come on and the
buzzer goes off.
Alarm monitors are located on the control
panel. Under normal conditions, the moni-
tors are off. When there is a problem, the
monitors light up.
(4) Alarm Devices
Check that the pilot lamps on the
instrument panel are as shown below when
the starter key is turned on:
NOTE:
All these signals will continue until the en-
gine starts up or the key is turned off.
Low L.O. pressure alarm lamp Lit
Pilot
Charge lamp Lit
lamps
Cooling water temp. alarm lamp Off
Controls and Equipment Mechanism
Option
KM4A Clutch
KMH4A Clutch