XK3190A12(E)
10
3.4 COUNTING
At weighing mode, press [Func] to enter the counting mode. Indicator displays “count”, and we can load
the scale. When stable indication sign is on, press [
*
] key, indicator displays “C00000”, then press [Tare] to
move the small indication triangle directedly, the number corresponded with the small triangle means the
sample quantity, and this number will increase by one when press [Zero] key. After inputting the sample
quantity, press [
*
] key to start the counting. The counting indication sign will be on.
At counting mode, press [Func] key to return to weighing mode.
Note:
When “count” is displayed after we pressing [Func] key at the weighing mode, press [
*
] twice to enter
counting mode directly. Indicator will count according to last time sampling result.
In this process, if theErr 4appears, it means sampling failed, the indicator will keep the result of last
sampling.
3.5 ACCUMULATING
At weighing mode, when the displaying value is positive and stable, press [
*
] key to accumulate the
present weight. Press [
*
] key again, it gets back to weighing mode. The next accumulating operation must
be performed after the weight return to zero. When the scale displaying zero, press [
*
] to display the
accumulated weight.
At accumulating mode, press [Func] key to clear the accumulated weight in Memory.
3.6 USER FUNCTIONS SETTING
At weighing mode, keeping pressing [Func] for more than 5 seconds, it enters user functions setting
mode (mode P). There are 9 parameters. Press [
*
] to change the parameter, and press [Tare] to change
the value. After setting the parameters, press [Func] to save.
Note: The parameters P6, P7, P8, and P9 are metrological related. We need to press the calibration switch
on the back housing to save the settings.
Parameters are as below:
1P1 x Automatically power off (Default setting:1)
X=1: Close this function
X=2: Auto power off 10 minutes after last operation
X=3 Auto power off 20 minutes after last operation
X=4 Auto power off 30 minutes after last operation
2P2 x Baud rate setting (Default setting:4)
X=1: 9600
X=2: 4800
X=3: 2400
X=4: 1200
3P3 x RS232 output content (Default setting:1)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yaohua Weighing System XK3190-A12 and is the answer not in the manual?

Yaohua Weighing System XK3190-A12 Specifications

General IconGeneral
BrandYaohua Weighing System
ModelXK3190-A12
CategoryAccessories
LanguageEnglish

Related product manuals