XK3190-A12(E)
X=1: Net weight output
X=2: Gross weight output
4、P4 x RS232 output mode (Default setting:1)
X=1: No transmission (RS232 stop)
X=2: Continuous transmission
X=3: Continuous transmission only when stable
5、P5 x Backlight mode (Default setting:2)
X=1: No backlight
X=2: Automatic backlight
X=3: Constant backlight
6、P6 x Zero-tracking range (Default setting:1)
X=1: 0.5e
X=2: No zero tracking
7、P7 x Digital filtering intensity (Default setting:2)
X=1: High
X=2: Medium
X=3: Low
8、P8 x Stabling speed (Default setting:2)
X=1: Fast
X=2: Medium
X=3: Slow
9、P9 x Stable range (Default setting:2)
X=1: Wide
X=2: Medium
X=3: Narrow
3.7 SERIAL COMMUNICATION (RS232)
■ Make sure that communication interfaces are correctly connected. If there is anything wrong with the
connection, damage may happen to output port of the indicator, input port of the computer, and even
other peripherals may get involved.
■ Necessary computer technology and programming skills are required for computer communication,
which should be participated and instructed by professionals. Non-professional staff is supposed not to
be involved in this regard.
■ Detailed connection instruction kindly check the 2.3.3 on page 8
Data for RS232 communication is in ASCII code. The format is as below:
The 1
st
bit is starting bit, the 10
th
bit is stopping bit, and the middle 8 bits are data bits. Even check.