18
YASKAWA
|
YASKAWA AC Drive
CH700
Catalog
|
KAEP C710617 24
Model Number
Drives can be customized according to your specifications.
CIPR
-
CH70 A 2 003 A B A A
-
G A A A A A
1 2 3 4
5 6 7 8
9 10 11 12 13 14
Product series
・
CH7
00
series
Input power supply voltage
・
2
:
3
-
phase AC
200
V Class
・
4
:
3
-
phase AC
400
V Class
EMC noise filter
・
A
:
No internal EMC filter
(
Standard
)
・
B
:
Internal category C
3
EMC filter
・
C
:
Internal category C
2
EMC filter
Enclosure Protection Design
・
B
:
IP
20
/UL Open Type
(
Standard
)
・
F
:
IP
20
/UL Type
1
Note
:
IP
20
/UL Type
1
is optional.
(
Install a UL Type
1
kit on an IP
20
/UL Open Type drive.
)
Environmental specifications
・
A
:
Standard
・
K
:
Gas
-
resistant
・
M
:
Humidity
-
resistant and dust
-
resistant
・
N
:
Oil
-
resistant
・
P
:
Humidity
-
resistant, dust
-
resistant, and vibration
-
resistant
・
R
:
Gas
-
resistant and vibration
-
resistant
・
S
:
Vibration
-
resistant
・
T
:
Oil
-
resistant and vibration
-
resistant
Note
:
Drives with these specifications do not guarantee complete
protection for the environmental conditions indicated.
1
:
Indicates the rated output current rounded off to the nearest whole number.
Refer to Rated Output Current column on page
22
to
23
for detailed values.
2
:
A separate cable must be purchased to connect the drive and the keypad.
Refer to Keypad Extension Cable on page
60
for more details.
Catalog Code
CH70 A 2 003 A B A
Selecting the Capacity
Note
:
IP20/UL Type 1 is optional.
(
Install a UL Type 1 kit on an IP20/UL
Open Type drive.
)
Note
:
Drives with these specifications do not
guarantee complete protection for the
environmental conditions indicated.
When using the drive for shaft spinning, traversing, and traveling, the drive should be selected so that the rated output current of
the drive output amps are equal to or greater than the motor rated current.
When using the drive for a lifting shaft, the current upon startup must be maintained to 150% or less of the rated output current.
Yaskawa recommends selecting the drive according to the following formula.
Formula
:
rated output current of the drive
×
coefficient
(
0.6 to 0.9
)
>
motor rated current
Coefficient for each control mode
·
Closed Loop Vector Control
:
0.9
·
Open Loop Vector Control, Advanced Open Loop Vector Control
:
0.8
·
V/f Control*
,
Closed Loop V/f Control
:
0.7
:
When driving multiple motors using one drive, it is calculated with a coefficient of
0
.
6
.
Calculate the motor rated current by the total value of two or more motors.
No. Input power supply voltage
2 3
-
Phase 200 V Class
4 3
-
Phase 400 V Class
Output Current
Note
:
Indicates the
rated output
current rounded
off to the nearest
whole number.
*
CE, RCM Marking compliant model.
No.
Enclosure Protection Design
B IP
20
/UL Open Type
F IP
20
/UL Type
1
No. Environmental Specifications
A Standard
K Gas
M Humidity, dust
N Oil
P Moisture, dust, vibration
R Gas, vibration
S Shock, vibration
T Oil, vibration
Internal EMC filter
(
C
2
)
*
Internal EMC filter
(
C
3
)
*
Control circuit terminal board
・
G
:
10
digital input, screw clamp terminal board type
Option card
(
connector CN
5
-
A
)
・
A
:
No option card
(
Standard
)
・
D
:
AI
-
A
3
(
Analog Input
)
・
E
:
DI
-
A
3
(
Digital Input
)
・
F
:
SI
-
C
3
(
CC
-
Link
)
・G
:
SI
-
ET3
(
MECHATROLINK
-
III
)
・
H
:
SI
-
N
3
(
DeviceNet
)
・
J
:
SI
-
P
3
(
PROFIBUS
-
DP
)
・K
:
SI
-
T3
(
MECHATROLINK
-
II
)
・
M
:
SI
-
S
3
(
CANopen
)
・S
:
SI
-
EP3
(
PROFINET
)
Option card
(
connector CN
5
-
B
)
・
A
:
No option card
(
Standard
)
・
B
:
AO
-
A
3
(
Analog Monitor
)
・
C
:
DO
-
A
3
(
Digital Output
)
Option card
(
connector CN
5
-
C
)
・
A
:
No option card
(
Standard
)
・
U
:
PG
-
B
3
(
Complementary Type PG
)
・
V
:
PG
-
X
3
(
Motor PG Feedback Line Driver Interface
)
・
Y
:
PG
-
RT
3
(
Motor Feedback Resolver TS
2640
N
321
E
64
Interface
)
Keypad
・
A
:
LCD keypad
(
Standard
)
*
2
・
B
:
LCD keypad
(
humidity
-
resistant and dust
-
resistant
)
*
2
・
D
:
Bluetooth LCD Keypad
*
2
・
E
:
Bluetooth LCD Keypad
(
humidity
-
resistant and dust
-
resistant
)
*
2
・
F
:
LED keypad
*
2
・
G
:
LED keypad
(
humidity
-
resistant and dust
-
resistant
)
*
2
Special applications
・
A
:
Standard