11
Table
2 Constants List
Con-
Change
during
Control Method
(f=Setting enable
×=Setting disable)
Function Display
Display
stant
No.
Constant Name
Range
Factory Setting
Operation
(f=Enable,
×=Disable)
Data Selection
V/f
Control
V/f with
PG
Feed-
back
Open
Loop
Vector
Flux
Vector
PG Pulse/Rev F1−01 PG constant 0 to 60000 1624
*3
× ×
f
×
f
PG Fdbk Loss Sel F1−02 Operation selection at PG open circuit 0to3 1 ×
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast−Stop
3 : Alarm Only
×
f
×
f
PG Overspeed Sel F1−03 Operation selection at overspeed 0to3 1
×
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast−Stop
3 : Alarm Only
×
f
×
f
PG Deviation Sel F1−04 Operation selection at deviation 0to3 3 ×
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast−Stop
3 : Alarm Only
×
f
×
f
PG Option Setup
PG Rotation Sel F1−05 PG rotation 0/1 0 ×
0 : Fwd=C.C.W.
1 : Fwd=C.W.
×
f
×
f
PG Output Ratio F1−06 PG division rate 1 to 132 1
× ×
f
×
f
PG Ramp PI/I Sel F1−07
Integral value during accel/decel
enable/disable
0/1 0 ×
0 : Disabled
1 : Enabled
×
f
× ×
PG Overspd Level F1−08 PG overspeed detection level 0 to 120% 115%
× ×
f
×
f
PG Overspd Time F1−09 PG overspeed detection delay time 0 to 2.0s 0.0s
*1
× ×
f
×
f
PG Deviate Level F1−10 Excessive speed deviation detection level 0 to 50% 10% × ×
f
×
f
PG Deviate Time F1−11
Excessive speed deviation detection
delay time
0 to 2.0s 0.5s
× ×
f
×
f
PG # Gear Teeth 1 F1−12 Number of PG gear teeth 1 0 to 1000 0
× ×
f
× ×
PG # Gear Teeth 2 F1−13 Number of PG gear teeth 2 0 to 1000 0
× ×
f
× ×
PGO Detect time
*4
F1−14 PG open circuit detection delay time 0.0 to 10,0 2.0s × ×
f
×
f
ASR P Gain 1 C5−01 ASR proportional gain 1 0 to 300.00 20.00
*1
(0.00)
*2
f
×
f
×
f
ASR I Time 1 C5−02 ASR integral time 1 0 to 10.000s 0.500s
*1
(1.000s)
*2
f
×
f
×
f
ASR P Gain 2 C5−03 ASR proportional gain 2 0 to 300.00 20.00
*1
(0.20)
*2
f
×
f
×
f
ASR I Time 2 C5−04 ASR integral time 2 0 to 10.000s 0.500s
*1
(1.000s)
*2
f
×
f
×
f
ASR Tuning
*5
ASR Limit C5−05 ASR limit 0.0 to 20.0% 5.0%
*2
× ×
f
× ×
ASR Delay Time C5−06 ASR primary delay time
0.000 to
0.500s
0.004s *
1
× × × ×
f
ASR Gain SW Freq C5−07 ASR switching frequency
0.0 to
400.0Hz
0.0Hz
× × × ×
f
*1 Flux vector control *2 V/f with PG feedback control *3 Value when o2−09=1 or 2
*4 Setting and reference are enabled for the software No. (U1−14) of 0130 or after. *5 ASR = Automatic Speed Regulation
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France