32
1. Upper limit of setting range and initial setting are doubled at 400 class.
2. Changes depending on inverter capacity. Refer to the next page.
3. Initial setting of the model with digital operator (without volume) is 1.
Setting can be set to 0 by parameter initialization.
70 0146H Slave address
Setting unit: 1
Setting range: 0 ~ 32
0-
71 0147H Baud rate selection
0: 2400 bps
1: 4800 bps
2: 9600 bps
3: 19200 bps
2-
72 0148H Parity selection
0: Even parity
1: Odd parity
2: No parity
0-
73 0149H Send waiting time
Setting unit: 1 = 1ms
Setting range: 10 ~ 65 ms
10ms -
74 014AH RTS control
0: RTS control enabled.
1: RTS control disabled.
0-
75
76
0: Execution completed / execution
command receive condition
1: READ execute
2: COPY execute
3: VRFY execute
4: kVA display
5: Software No. display
77
0: READ prohibited.
1: READ allowed.
78 014EH Fault history
The 1 newest event is displayed
(Note) Setting is disabled.
-54
79 014FH Software No.
Lower 3 digits of software numbers are
displayed.
(Note): Setting is disabled.
--
No.
Register
No. for
Trans-
mission
Name
Initial
Setting
User
Setting
Ref.
Page