33
• KVA Dependant Parameter Default Settings
200V class 3-phase
200V class single-phase
400V class 3-phase
No. Name Unit Factory setting
– Inverter capacity kW 0.1kW 0.2kW 0.4kW 0.75kW 1.5kW 2.2kW – 3.7kW
n32 Motor rated current A 0.6 1.1 1.9 3.3 6.2 8.5 – 14.1
n64 Motor rated slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 – 3.3
n65
Motor no-load
current
%727362554535 – 32
No. Name Unit Factory setting
– Inverter capacity kW 0.1kW 0.2kW 0.4kW 0.75kW 1.5kW 2.2kW – 3.7kW
n32 Motor rated current A 0.6 1.1 1.9 3.3 6.2 8.5 – 14.1
n64 Motor rated slip Hz 2.5 2.6 2.9 2.5 2.6 2.9 – 3.3
n65
Motor no-load
current
%727362554535 – 32
No. Name Unit Factory setting
– Inverter capacity kW – 0.2kW 0.4kW 0.75kW 1.5kW 2.2kW – 3.7kW
n32 Motor rated current A – 0.6 1.0 1.6 3.1 4.2 7.0 7.0
n64 Motor rated slip Hz – 2.5 2.7 2.6 2.5 3.0 3.2 3.2
n65
Motor no-load
current
% – 73 63 52 45 35 33 33