377
Phone UI
Menu > Features > Anonymous Call > Send Anonymous Code (Send Anony Code)
Parameter
account.X.anonymous_call.server_base_only
[1]
<MAC>.cfg
Description
It enables or disables the phone to perform the anonymous call feature on server-side only.
Note: You need to configure parameters “account.X.anonymous_call_oncode” and “accoun-
t.X.anonymous_call_offcode to activate and deactivate the server-side anonymous call feature.
Permitted
Values
0-Disabled, the phone will perform the anonymous call feature on server-side and locally. If the
anonymous call feature is enabled on the phone, the phone will carry the Anonymous attribute in the
From header of the INVITE message.
1-Enabled, the phone will perform the anonymous call feature on server-side only. The phone will not
carry the Anonymous attribute in the From header of the INVITE message even if the anonymous call
feature is enabled on the phone.
Default
Blank
Parameter
account.X.anonymous_call_oncode
[1]
<MAC>.cfg
Description
It configures the anonymous call on code.
The phone will send the code to activate the anonymous call feature on server-side when you activate
it on the phone.
Permitted
Values
String within 32 characters
Default
Blank
Web UI
Account > Basic > Send Anonymous Code > On Code
Phone UI
Menu > Features > Anonymous Call > On Code
Parameter
account.X.anonymous_call_offcode
[1]
<MAC>.cfg
Description
It configures the anonymous call off code.
The phone will send the code to deactivate the anonymous call feature on server-side when you deac-
tivate it on the phone.
Permitted
Values
String within 32 characters
Default
Blank
Web UI
Account > Basic > Send Anonymous Code > Off Code
Phone UI
Menu > Features > Anonymous Call > Off Code
[1]
X is the account ID. For T57W/T54W/T48U/T48S/T48G/T46U/T46S/T46G/T29G, X=1-16; for
T53W/T53/T43U/T42G/T42U/T42S, X=1-12; for T41P/T41S/T27G, X=1-6; for T40P/T40G/T23P/T23G, X=1-3; for T21
(P) E2, X=1-2; for T19(P) E2/CP920, X=1.
Call Number Filter
Call number filter feature allows IP phone to filter designated characters automatically when dialing.
Topic
Call Number Filter Configuration
Call Number Filter Configuration
The following table lists the parameter you can use to configure call number filter.

Table of Contents

Other manuals for Yealink SIP-T53W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T53W and is the answer not in the manual?

Yealink SIP-T53W Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP mobile phone
Product colorGray
Keypad illuminationYes
Wi-Fi standards802.11a, 802.11g, Wi-Fi 4 (802.11n)
Bluetooth version4.2
Security algorithmsAES, HTTPS, SIPS
Networking standardsIEEE 802.1p, IEEE 802.1x, IEEE 802.3af
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsFTP/TFTP/HTTP/HTTPS
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports2
Lines quantity8 lines
Phonebook capacity1000 entries
Number of VoIP accounts12
AC adapter input voltage100 - 240 V
AC adapter output current1.2 A
AC adapter output voltage5 V
Power consumption (typical)2.3 W
Volume controlButtons
Number of programmable keys8
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Display diagonal3.7 \
Display resolution360 x 160 pixels
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
Number of DECT wireless handsets4
Voice codecsG.722, G.723.1, G.726, G.729A, G.729B, OPUS, iLBC
Weight and Dimensions IconWeight and Dimensions
Depth210.6 mm
Width212 mm
Height174.5 mm