Administrator’s Guide for SIP-T2 Series/T4 Series/T5 Series/CP920 IP Phones
526
Alcatel-Lucent Barge in Parameters
If you want to use Barge In feature, you should configure a feature access code on the phone. If no feature access
code is configured, the Barge In feature is disabled.
Parameter
blf.normal_barge_in_code <y0000000000xx>.cfg
Description
It configures the feature access code for normally barging in the active call of the monitored line.
If configured, you can press the Barge In soft key to barge in the call. Barge-in plays an audio alert to
indicate the arrival of a new participant to the call and all call participants can interact.
Note: It applies to the Alcatel-Lucent CTS only.
Permitted
Values
String within 32 characters
Default
Blank
Supported
Devices
All phones except T48G, T46G, T42G, T41P, T29G, T19(P) E2 and CP920
Case Scen-
ario
The feature access code is *32. A (your phone) monitors party B (number: 8866), party B and party C
is during the call.
Set the following:
blf.normal_barge_in_code = *32
features.blf.show_callinfo.enable = 1
During the call of the monitored line, long press the BLF key and press the Barge In soft key, then the
phone calls *328866 to barge in the call. All call participants can interact during the call.
Related
Parameters
features.blf.show_callinfo.enable
Parameter
blf.whisper_barge_in_code <y0000000000xx>.cfg
Description
It configures the feature access code for barging in the active call of the monitored line in whisper.
If configured, you can press the Whisper BargeIn soft key to barge in the call. You can hear all call
participants but your audio can only be transmitted to the user you are monitoring.
Note: It applies to the Alcatel-Lucent CTS only.
Permitted
Values
String within 32 characters
Default
Blank
Supported
Devices
All phones except T48G, T46G, T42G, T41P, T29G, T19(P) E2 and CP920
Case Scen-
ario
The feature access code is *32. A (your phone) monitors party B (number: 8866), party B and party C
is during the call.
Set the following:
blf.whisper_barge_in_code = *32
features.blf.show_callinfo.enable = 1
During the call of the monitored line, long press the BLF key and press the Whisper BargeIn soft key,
then the phone calls *328866 to barge in the call. You can hear all call participants, but only party B
can hear you.
Related
Parameters
features.blf.show_callinfo.enable

Table of Contents

Other manuals for Yealink SIP-T53W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T53W and is the answer not in the manual?

Yealink SIP-T53W Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP mobile phone
Product colorGray
Keypad illuminationYes
Wi-Fi standards802.11a, 802.11g, Wi-Fi 4 (802.11n)
Bluetooth version4.2
Security algorithmsAES, HTTPS, SIPS
Networking standardsIEEE 802.1p, IEEE 802.1x, IEEE 802.3af
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsFTP/TFTP/HTTP/HTTPS
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports2
Lines quantity8 lines
Phonebook capacity1000 entries
Number of VoIP accounts12
AC adapter input voltage100 - 240 V
AC adapter output current1.2 A
AC adapter output voltage5 V
Power consumption (typical)2.3 W
Volume controlButtons
Number of programmable keys8
Storage temperature (T-T)-30 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Display diagonal3.7 \
Display resolution360 x 160 pixels
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
Number of DECT wireless handsets4
Voice codecsG.722, G.723.1, G.726, G.729A, G.729B, OPUS, iLBC
Weight and Dimensions IconWeight and Dimensions
Depth210.6 mm
Width212 mm
Height174.5 mm

Related product manuals