Unitary Products Group 13
035-16004-001-A-0202
INDOOR DB
TEMPERATURE,
°F
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
-100 102030405060
55 8.3 8.4 8.6 9.0 10.1 12.4 17.4 28.6
70 -----4.29.220.4
80 ------5.716.9
TABLE 18 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HA048)
TABLE 17 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HA048)
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 11.4 12.4 13.5 14.6 15.7 16.8 17.9 19.3 20.7 22.1 23.5
70 10.3 11.2 12.2 13.1 14.0 14.9 15.9 17.4 18.9 20.4 21.9
75 9.3 10.0 10.8 11.6 12.3 13.1 13.9 15.4 17.0 18.6 20.2
80 8.2 8.8 9.4 10.0 10.6 11.2 11.8 13.5 15.2 16.9 18.5
85 7.2 7.7 8.1 8.5 9.0 9.4 9.8 11.6 13.4 15.1 16.9
90 6.5 7.0 7.4 7.9 8.3 8.8 9.2 10.6 12.0 13.4 14.8
95 5.9 6.3 6.8 7.2 7.7 8.1 8.6 9.6 10.6 11.6 12.6
100 - 5.5 6.1 6.6 7.2 7.8 8.4 9.3 10.3 11.3 12.3
105 - - 5.4 6.1 6.8 7.5 8.2 9.1 10.1 11.0 11.9
110 - - - 5.5 6.3 7.2 8.0 8.9 9.8 10.7 11.6
115 ----5.96.97.88.79.510.4 11.2
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 26.7 27.6 28.5 29.4 30.3 31.2 32.1 33.0 33.9 34.8 35.7
70 21.9 23.0 24.1 25.2 26.3 27.4 28.5 30.0 31.4 32.8 34.3
75 17.0 18.3 19.7 21.0 22.3 23.7 25.0 27.0 28.9 30.9 32.9
80 12.2 13.7 15.3 16.8 18.4 19.9 21.5 24.0 26.5 29.0 31.4
85 7.3 9.1 10.8 12.6 14.4 16.2 17.9 20.9 24.0 27.0 30.0
90 7.2 8.3 9.4 10.6 11.7 12.8 13.9 17.3 20.6 23.9 27.2
95 7.0 7.5 8.0 8.5 9.0 9.5 9.9 13.6 17.2 20.8 24.4
100 7.2 7.6 8.0 8.3 8.7 9.1 9.5 12.4 15.3 18.2 21.1
105 7.4 7.7 7.9 8.2 8.5 8.7 9.0 11.2 13.4 15.6 17.8
110 7.6 7.8 7.9 8.1 8.2 8.4 8.5 10.0 11.5 13.0 14.4
115 7.8 7.8 7.9 7.9 8.0 8.0 8.1 8.8 9.6 10.3 11.1
TABLE 20 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HA060)
TABLE 19 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HA060)
INDOOR DB
TEMPERATURE,
°F
OUTDOOR TEMPERATURE, °F
-100 102030405060
55 5.5 5.7 6.2 6.8 8.0 9.9 13.1 18.6
70 -----4.88.013.4
80 ------5.611.0