036-21024-006 Rev. D (0403)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
TECHNICAL GUIDE
STELLAR 2000
TM
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER
MODELS: H*DB018 THRU 060
(1 THRU 5 NOMINAL TONS, 1 PH)
H*DB036 THRU 076
(3 THRU 6-1/3 NOMINAL TONS, 3 PH)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
Models 018-048
Model 060
LISTED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Certification applies only
when the complete
system is listed
with ARI.
R
N
E
M
P
I
U
Q
E
T
Y
R
A
T
I
N
U
0
1
2
A
R
I
R
A
D
N
A
T
S
D
I
S
N
O
T
C
E
S
F
O
C
C
I
F
I
T
R
E
N
O
I
T
A
H
T
I
W
C
G
N
I
Y
L
P
M
O
S
A
I
R
A
O
T
D
E
I
F
I
T
R
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
-
G
N
I
N
O
I
T
I
D
N
O
R
I
A
DESCRIPTION
The HDB Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of YORK's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - Cabinet is made of powder painted
steel over pre-primered steel. The pre-treated galvanized
steel provides a better paint to steel bond, which resists
corrosion and rust creep. Special primer formulas and
automotive quality finish insure less fading when exposed
to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Both quick connect and sweat connect
models are available. Both service valves are firmly affixed
to the unit. The sweat unit contains enough refrigerant for
matching indoor coils and 15 feet of interconnecting pip-
ing. The small base dimension means less space is
required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant
connections, a single panel covering the electrical con-
trols, and the molex plug in the control box connecting the
condenser fan make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York H4DB036 and is the answer not in the manual?

York H4DB036 Specifications

General IconGeneral
Tonnage3 Ton
RefrigerantR-410A
Cooling Capacity36000 BTU/h
Heating Capacity36000 BTU/h
Power Supply208/230V, 1 Phase, 60Hz
Sound Pressure Level (Indoor)45 dB

Summary

DESCRIPTION

FEATURES

Details key attributes like quality coils, compressor protection, durable finish, and ease of service.

PHYSICAL AND ELECTRICAL DATA - 1 PHASE

PHYSICAL AND ELECTRICAL DATA - 3 PHASE

Provides detailed specifications for single and three-phase models including voltage, amps, motor details, and dimensions.

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase

PROCEDURES

Outlines steps for verifying and adjusting refrigerant charge and orifice size for matched systems.

Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase

PROCEDURES

Details procedures for calculating and verifying refrigerant charge and orifice size for 3-phase systems.

COOLING CAPACITY - With Air Handler Coils

1 PH 10 SEER AC WITH N1AH / G2FD

Lists cooling capacities (MBH, SEER, EER) for 1-phase outdoor units matched with specific N1AH/G2FD air handler coils.

3 PH 10 SEER AC / N1VS - VARIABLE SPEED

Presents cooling performance data (MBH, SEER, EER) for 3-phase outdoor units with N1VS variable speed air handlers.

1 PH 10 SEER AC / N1VS - VARIABLE SPEED

Shows cooling performance for 1-phase outdoor units with N1VS variable speed air handlers.

1 PH 10 SEER AC / F2RP/RC/FP/FC

Details cooling capacities for 1-phase outdoor units matched with F2RP/RC/FP/FC fan coil units.

COOLING CAPACITY - With Air Handler Coils (Continued)

3 PH 10 SEER AC / F2RP / RC / FP / FC

Lists cooling performance data for 3-phase outdoor units with F2RP/RC/FP/FC fan coil units.

3 PH SEER AC / K2EU

Provides cooling capacity data for 3-phase outdoor units with K2EU air handlers.

1 PH 10 SEER AC / M1HC

Details cooling capacities for 1-phase outdoor units with M1HC air handlers.

COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils

H4DB018

Cooling performance data for H4DB018 outdoor units matched with specific furnace and coil combinations.

H4DB024

Cooling performance data for H4DB024 outdoor units matched with specific furnace and coil combinations.

H4DB030

Cooling performance data for H4DB030 outdoor units matched with specific furnace and coil combinations.

H4DB036S06

Cooling performance data for H4DB036S06 outdoor units matched with specific furnace and coil combinations.

COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils (Continued)

H4DB036S25,4 6

Cooling performance data for H4DB036S25,46 outdoor units matched with specific furnace and coil combinations.

H5DB042

Cooling performance data for H5DB042 outdoor units matched with specific furnace and coil combinations.

H5DB048

Cooling performance data for H5DB048 outdoor units matched with specific furnace and coil combinations.

H4DB060S06

Cooling performance data for H4DB060S06 outdoor units matched with specific furnace and coil combinations.

H4DB060S25,4 6

Cooling performance data for H4DB060S25,46 outdoor units matched with specific furnace and coil combinations.

COOLING PERFORMANCE

H4DB018

Cooling performance data (TC, SC, KW) for H4DB018 model at various condenser temperatures and airflow.

H4DB024

Cooling performance data (TC, SC, KW) for H4DB024 model at various condenser temperatures and airflow.

H4DB030

Cooling performance data (TC, SC, KW) for H4DB030 model at various condenser temperatures and airflow.

H4DB036

Cooling performance data (TC, SC, KW) for H4DB036 model at various condenser temperatures and airflow.

H5DB042

Cooling performance data (TC, SC, KW) for H5DB042 model at various condenser temperatures and airflow.

H5DB048

Cooling performance data (TC, SC, KW) for H5DB048 model at various condenser temperatures and airflow.

H4DB060

Cooling performance data (TC, SC, KW) for H4DB060 model at various condenser temperatures and airflow.

H4DB076

Cooling performance data (TC, SC, KW) for H4DB076 model at various condenser temperatures and airflow.

TYPICAL FIELD WIRING - 1 PHASE APPLICATION

TYPICAL FIELD WIRING - 3 PHASE APPLICATION

Illustrates typical wiring diagrams for single-phase and three-phase applications, including control and power connections.

ACCESSORIES

SOUND RATINGS

Lists sound ratings (decibels) for various outdoor unit models.

1 PHASE

Details dimensions and refrigerant line sizes for 1-phase outdoor units.

3 PHASE

Provides dimensions and refrigerant line sizes for 3-phase outdoor units.

COOLING PERFORMANCE DATA

H4DB018

Presents detailed cooling performance data (TC, SC, KW) for the H4DB018 model with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Provides multipliers to adjust performance based on different indoor coil selections.

COOLING PERFORMANCE DATA

H4DB024

Detailed cooling performance data (TC, SC, KW) for the H4DB024 model with various indoor coils.

Multipliers for determining the performance with other indoor sections.

Lists multipliers to adjust cooling performance based on the chosen indoor coil.

COOLING PERFORMANCE DATA

H4DB030

Detailed cooling performance data (TC, SC, KW) for the H4DB030 model with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Provides multipliers for adjusting cooling performance based on different indoor coil pairings.

COOLING PERFORMANCE DATA

H4DB036

Detailed cooling performance data (TC, SC, KW) for the H4DB036 model with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Lists multipliers to adjust cooling performance for various indoor coil matches.

COOLING PERFORMANCE DATA

H5DB042

Detailed cooling performance data (TC, SC, KW) for the H5DB042 model with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Provides multipliers for adjusting cooling performance based on different indoor coil selections.

COOLING PERFORMANCE DATA

H5DB048

Detailed cooling performance data (TC, SC, KW) for the H5DB048 model with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Lists multipliers to adjust cooling performance for various indoor coil pairings.

COOLING PERFORMANCE DATA

H4DB060

Detailed cooling performance data (TC, SC, KW) for the H4DB060 model with specific indoor coils.

H4DB060S25,46 ONLY

Cooling performance data for H4DB060S25,46 models with specific indoor coils.

Multipliers for determining the performance with other indoor sections.

Provides multipliers for adjusting cooling performance based on different indoor coil selections.

COOLING PERFORMANCE DATA

H4DB076

Detailed cooling performance data (TC, SC, KW) for the H4DB076 model with a specific indoor coil.

MATCHING INDOOR COMPONENTS

ADD-ON COILS - FOR FURNACE APPLICATIONS

Illustrates various add-on coils for furnace applications, categorized by type.

AIR HANDLERS - FOR NON-FURNACE APPLICATIONS

Shows different air handler models for non-furnace applications, including modular blowers and fan coil units.