EasyManua.ls Logo

York H4TS024 - Manual Change-Over Thermostat; Electronic Thermostat Operation; Start-Up Procedures; System Start-Up

York H4TS024
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
036-21023-005 Rev. A (0802)
Unitary Products Group 3
* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**
Refer to Quick Selection Chart for specific furnace match-up.
ACCESSORIES*
Enhanced Coil Guard - An enhanced coil guard which offers
superior protection from hail and other types of damage is
available.
* For the most current accessory information, refer to the
price book or consult factory.
SOUND RATINGS*
*Rated in accordance with ARI Standard 270.
COOLING CAPACITY -With Air Handler Coils
UNIT
MODEL
VAR SPEED AIR HANDLER
COIL MODEL
COOLING
MODEL
ELEC. HEAT
KW
W
STAGE
(# CYL)
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
H4TS024 N+VSB12 5,7.5,10,15,18 17
G2FD024S17
1 600 12.4 10.0
14.8
13.5
2 820 24.0 16.8 12.0
G2FD030S17
1 600 12.8 10.2
15.4
14.0
2 820 24.6 17.2 12.5
G2FD036S17
1 600 13.0 10.4
15.5
14.3
2 820 25.0 17.5 12.5
H4TS030
N-VSB12 5,7.5,10,15,18 17
G2FD030S17
1 670 15.0 12.0
14.0
12.7
2 1035 30.0 21.6 11.0
G2FD036S17
1 670 15.4 12.2
14.5
13.1
2 1035 31.0 22.0 11.0
N-VSC16 5,7.5,10,15,20 21 G2FD042S21
1 690 16.4 13.4
15.3
14.1
2 1065 31.6 23.4 11.2
H4TS036 N-VSC16 5,7.5,10,15,20 21
G2FD036S21
1 770 20.0 16.0
15.0
13.7
2 1185 35.0 26.0 11.3
G2FD042S21
1 770 20.0 16.0
15.0
13.7
2 1185 35.0 26.0 11.3
G2FD048S21
1 770 20.6 16.6
16.0
14.4
2 1185 36.0 26.6 12.5
H4TS048
N-VSC16 5, 7.5,10,15,20 21 G2FD048S21
1 1050 25.0 20.0
15.2
14.1
2 1605 47.5 35.0 10.4
N-VSD20 5, 7.5,10,15,20 24
G2FD048S24
1 1050 25.0 20.0
15.3
14.2
2 1570 47.5 35.0 10.5
G2FD060S24
1 1050 25.0 21.0
15.5
14.0
2 1570 49.5 37.0 10.7
H4TS060 N-VSD20 5, 7.5,10,15,20 24
G2FD060S24
1 1250 33.0 26.4
14.5
13.5
2 1900 59.0 43.0 10.4
G2FD061H24
1 1250 33.0 26.4
15.0
14.0
2 1900 59.5 44.0 10.7
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
UNIT MODEL
SOUND RATINGS
DECIBELS
1 CYLINDER 2 CYLINDER
024 70 db 72 db
030 72 db 74 db
036 73 db 74 db
048 76 db 78 db
060 78 db 79 db

Other manuals for York H4TS024