TECHNICAL GUIDE
SPLIT-SYSTEM
AIR-COOLED CONDENSING UNITS
HA300, HB360, HB480 & HB600
25 thru 50 NOMINAL TONS
(50 Hz)
ISO 9001
Certified Quality
Management System
036-21345-001-B-0105
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
DESCRIPTION
These units are completely assembled, piped and wired at the factory
to provide one-piece shipment and rigging. Each unit is pressurized
with a holding charge of refrigerant-22 for storage and/or shipping.
The compact design, clean styling, low silhouette, and quiet operation
make these condensing units suitable for almost any outdoor location.
On rooftops . . . because they weigh much less than a single package
unit of similar capacity and are much easier to rig and support. At
ground level . . . because their ample sub-cooling capacity allows them
to be located three or more stories below the evaporator coil.
Every condenser coil is pressurized with air to 325 psig and leak
tested under water. After assembly, the unit is pressurized with a com-
bination of refrigerant-22 and nitrogen to 450 psig for pressure testing
and additional leak testing. During this pressure test, the operation of
the high pressure control is checked. As the unit is being evacuated
and dehydrated, the operation of the low pressure control is checked.
Every compressor, condenser fan motor, crankcase heater, and elec-
trical control circuit is checked to assure a trouble-free start-up and
years of reliable operation.
The condenser fan guards are vinyl-coated to provide additional rust
protection and to enhance the appearance of the unit.
Compressors are mounted on rubber isolators to reduce the transmis-
sion of vibration. Vertical discharge condenser fans direct sound
upward and away from any surrounding structures.
All sheet metal parts are constructed of commercial grade (G90) gal-
vanized steel. After fabrication, each part is thoroughly cleaned to
remove any grease or dirt from its surfaces. The external parts are
coated with a powder paint to assure a quality finish for many years.
This UL approved coating system has passed the 1000 hour, 20% salt
spray test per ASTM Standard B117.
A matching line of Evaporator Blower units is also offered to meet your
precise capacity and air handling requirements.
Question and Answer IconNeed help?

Do you have a question about the York HB360 and is the answer not in the manual?

York HB360 Specifications

General IconGeneral
BrandYork
ModelHB360
CategoryAir Conditioner
LanguageEnglish

Summary

Technical Guide Overview

Split-System Air-Cooled Condensing Units

Specifics for HA300, HB360, HB480 & HB600 models, 25-50 nominal tons (50 Hz).

Product Features

Compressor and Coil Features

Copeland Scroll compressors and copper tube/aluminum fin condenser coils for efficiency and durability.

Product Nomenclature

Model Number Breakdown

Detailed breakdown of model number components: Product Category, Identifier, Capacity, Heat Type, etc.

Refrigerant Line Sizing

Field Wiring Diagrams

HA300 & LA300 Wiring Diagram

Typical field wiring diagram for HA300 and LA300 split systems, showing connections to thermostat and control boxes.

Unit Wiring and Fan Orientation

HB360, 480, 600 & LB360, 480, 600 Wiring Diagram

Field wiring diagram for HB360, 480, 600 and LB360, 480, 600 models, showing connections to thermostat and control boxes.

Piping and Electrical Connection Sizes

25 Ton Unit Connection Sizes

Specifies connection entry sizes for suction, liquid lines, power wiring, and control wiring for 25 Ton units.

30/40/50 Ton Unit Connection Sizes

Specifies connection entry sizes for suction, liquid lines, power wiring, and control wiring for 30/40/50 Ton units.

Guide Specifications

Installer Responsibilities and Unit Compliance

Requirements for installers and unit compliance with standards and warranty.

Related product manuals