EasyManua.ls Logo

York PV8 User Manual

York PV8
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL GUIDE
AFFINITY
MODELS: PV8
GAS-FIRED
HIGH EFFICIENCY TWO STAGE VARIABLE
UPFLOW/HORIZONTAL FURNACES
STANDARD & LoNOx
80% AFUE
NATURAL GAS
80 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional ratin
g
information can be found at
EFFICIENCY
RATING
CERTIFIED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
036-21606-001 Rev. A (0804)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
Provides increased comfort level & very quiet unit opera-
tion
Field Selectable delay timer allows two stage operation w/
single stage thermostat
Acoustically insulated blower compartment for reduced
blower sound level
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
High velocity filter and side -return filter rack provided for
easy field installation.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
100% shut off main gas valve for extra safety.
Variable Speed ECM with large, quiet blower.
ClimaTrak Technology allows dealer to customize comfort
settings based on regional location.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum
comfort.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance
or service.
Insulated blower compartment for quiet operation.
Independent door removal for greater durability and ease
of access.
LoNOx models have been designed to meet specific code
requirements.
LoNOx models may not be converted to propane.
Question and Answer IconNeed help?

Do you have a question about the York PV8 and is the answer not in the manual?

York PV8 Specifications

General IconGeneral
BrandYork
ModelPV8
CategoryFurnace
LanguageEnglish

Summary

Technical Guide Overview

Product Identification and Specifications

Identifies furnace series, model, fuel, and basic specifications.

Product Description

Provides a general overview of the furnace's features and applications.

Warranty Information

Outlines the warranty terms for the heat exchanger and parts.

Key Features

Lists key operational and design features of the furnaces.

Cabinet and Duct Dimensions

Cabinet and Duct Dimensions Table

Table detailing cabinet dimensions and duct sizes for various models.

Horizontal Venting Power Venting Kits

Specifies requirements for horizontal venting and power venting kits.

Horizontal Vent Lengths

Table showing minimum and maximum horizontal vent lengths for various airflow and pipe sizes.

Ratings and Electrical Data

Ratings and Physical/Electrical Data Table

Table with detailed specifications including input/output, airflow, AFUE, and electrical data.

Filter Sizes Table

Table specifying filter sizes for different cabinet configurations.

Field Wiring for Single Stage Thermostat

Diagram illustrating wiring connections for single-stage thermostats.

Field Wiring for Two Stage Thermostat

Diagram showing wiring for two-stage thermostat installations.

Air Flow Data

Cooling and Heat Pump Airflow Data

Table showing airflow data for cooling and heat pump operation.

Heating Airflow Data

Table detailing airflow specifications for heating-only operation.

Air Flow Data Notes

Important notes regarding airflow, static pressure, and voltage.

Filter Performance and Clearances

Filter Pressure Drop Data

Table showing pressure drop across different filter types and sizes.

Calculating System Airflow with Filters

Guide on how to calculate system airflow considering filter pressure drop.

Clearances to Combustibles Table

Table detailing required clearances to combustible materials for various installation configurations.

Accessories

Propane (LP) Conversion Kit

Details the kit for converting natural gas units to propane.

External Bottom Return Filter Rack

Describes the accessory filter rack and its availability for different cabinet sizes.

High Altitude Pressure Switches

Information on accessory kits for high altitude operation.

Field Installed Electrical Accessories

Table listing electrical accessories like thermostats and their compatibility.

Related product manuals