036-21021-003 Rev. C (0203)
8 Unitary Products Group
NOTES:
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15.superheat and 15...sub-cooling at condensing unit.
a. Increase capacity 1% for each 2 increase in sub-cooling.
b. Decrease capacity 1% for each 2 decrease in sub-cooling.
3. Sub-cooling in excess of 20 may result in excessively high condensing temperature with air on condenser above 115.
Maximum recommended condensing temperature is 140.
H4DE048S06
P1DUC20V G1FA048S21 21 1605 49.0 36.3 11.50 - 10.45
P1DUC20V G1FA060S21 21 1630 48.5 35.9 11.50 - 10.25
P1DUC20V G1UA048S21 21 1605 49.0 36.3 11.50 - 10.45
P1DUC20V G1UA060S21 21 1605 49.5 36.6 12.00 - 10.70
P1DUC20V G2FD048(S,H)21 21 1605 49.5 36.6 11.50 - 10.55
P1XUC16V G1FA048S21 21 1570 49.0 36.3 11.50 - 10.40
P1XUC16V G1FA060S21 21 1570 49.5 36.6 12.00 - 10.60
P1XUC16V G1UA048S21 21 1570 49.0 36.3 11.50 - 10.40
P1XUC16V G1UA060S21 21 1570 49.5 36.6 12.00 - 10.60
P1XUC16V G2FD048(S,H)21 21 1480 48.5 35.9 11.30 - 10.10
P1XUC20V G1FA048S21 21 1590 48.0 35.5 11.30 - 10.00
P1XUC20V G1FA060S21 21 1640 48.5 35.9 11.30 - 10.10
P1XUC20V G1UA048S21 21 1590 48.0 35.5 11.30 - 10.00
P1XUC20V G1UA060S21 21 1640 48.5 35.9 11.30 - 10.10
P1XUC20V G2FD048(S,H)21 21 1590 48.5 35.9 11.20 - 10.00
P1XUD20V G1FA060S24 24 1620 48.5 35.9 11.45 - 10.25
P1XUD20V G1UA060S24 24 1620 48.5 35.9 11.45 - 10.25
P1XUD20V G2FD048(S,H)24 24 1620 48.5 35.9 11.20 - 10.00
P1XUD20V G2FD060(S,H)24 24 1620 48.5 35.9 11.45 - 10.25
H4DE060S06
P1DUC20V G1FA060S21 21 1860 58.5 43.7 11.30 - 10.35
P1DUC20V G1UA060S21 21 1860 58.5 43.7 11.30 - 10.35
P1XUC20V G1FA060S21 21 1860 58.5 43.7 11.30 - 10.35
P1XUC20V G1UA060S21 21 1860 58.5 43.7 11.30 - 10.35
P1XUD20V G1FA060S24 24 1860 59.0 43.7 11.45 - 10.50
P1XUD20V G1UA060S24 24 1860 59.0 43.7 11.45 - 10.50
P1XUD20V G2FD060(S,H)24 24 1860 59.0 43.7 11.45 - 10.50
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.
COOLING PERFORMANCE
MODEL
SUCT. T/P @
COMPR.
AIR TEMP ON CONDENSER
MODEL
SUCT. T/P @
COMPR.
AIR TEMP ON CONDENSER
75° F95° F115° F75° F95° F115° F
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
H4DE024
35 61.5 24.2 2.34 16.8 2.35 10.5 2.30
H4DE042
35 61.5 38.1 3.22 34.1 3.81 30.0 4.56
40 68.5 27.0 2.40 19.1 2.43 12.3 2.39 40 68.5 41.5 3.26 37.2 3.86 32.9 4.61
45 76.0 29.9 2.47 21.5 2.52 14.2 2.48 45 76.0 45.0 3.30 40.5 3.91 35.9 4.67
50 84.0 33.0 2.54 24.0 2.61 16.1 2.58 50 84.0 48.5 3.35 43.8 3.96 39.0 4.73
H4DE030
35 61.5 24.4 2.41 20.2 2.75 16.1 3.07
H4DE048
35 61.5 44.4 4.01 39.8 4.77 35.2 5.69
40 68.5 27.5 2.48 22.9 2.85 18.4 3.18 40 68.5 48.5 4.09 43.7 4.88 38.8 5.82
45 76.0 30.7 2.56 25.7 2.94 20.8 3.30 45 76.0 52.8 4.18 47.7 4.98 42.5 5.95
50 84.0 34.0 2.63 28.6 3.03 23.2 3.42 50 84.0 57.2 4.27 51.9 5.09 46.4 6.09
H4DE036
35 61.5 31.9 2.95 26.4 3.46 21.3 4.19
H4DE060
35 61.5 58.6 4.52 51.3 5.54 44.2 6.85
40 68.5 35.1 2.99 29.1 3.51 23.6 4.25 40 68.5 63.6 4.60 56.0 5.63 48.5 6.95
45 76.0 38.3 3.04 32.0 3.58 26.0 4.31 45 76.0 68.7 4.68 60.7 5.71 52.8 7.03
50 84.0 41.7 3.11 34.9 3.65 28.5 4.39 50 84.0 73.9 4.76 65.5 5.80 57.2 7.12