Model YORK
Unit YHKJZH060BARXAFX
Outdoor YHUJYH060BASXA-X
Indoor YHKMXH060BARX-FX
Compressor
Model
LNB42FUAMC
Type
Rotary
Capacity W/h
47711
Input W
4270
Rated current(RLA) A
12
Locked rotor Amp(LRA) A
/
Thermal protector
120
Capacitor mF
/
Refrigerant oil ml
1400
Outdoor fan motor
Model
EHDS80BAS
Input W
120
Output W
100
Running current A
0.4
Capacitor uF
/
Speed rpm
930
Outdoor air ow m3/h
6500
Outdoor noise level (Sound power level) dB(A)
75
Outdoor noise level (Sound pressure level) dB(A)
60
Outdoor dimension
Unit (WxDxH) mm
948×340×1250
Packing (WxDxH) mm
1095×410×1400
Outdoor weight
Net kg 96
Gross kg
106
Refrigerant
Type
R410A
Charge g
3300
Refrigerant pipe
Liquid side mm
9.52
Gas side mm
19.05
Max. refrigerant pipe
length
m
50
Max. difference in level m
30
Operation temperature range
℃
16~30
Ambient temperature range (Cooling)
℃
-10~46
Ambient temperature range (Heating)
℃
-15~24