EasyManua.ls Logo

York YUFE60BYSM-MS-1 - Overload Current Protection Diagnosis and Solution

York YUFE60BYSM-MS-1
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Page 100
5.10 Overload current protection diagnosis and solution
Description: An abnormal current rise is detected by checking the specified current detection circuit.
Recommended parts to prepare:
Power supply problems.
System blockage
Faulty PCB
Wiring mistake
Compressor malfunction
Troubleshooting and repair:
Check the pow er supply.
D o a n y e x is t?
A re they w ithin acceptable
param eters?
Are they properly connected?
Is it in w orking order?
Replace the outdoor unit.
Is it in w orking order?
C heck system for blockages.
YES
Stop the unit.
NO
C lear the blockage.
NO
C heck the com pressor resistance values.
YES
Replace the com pressor.
NO
Check the connections and w ires.
YES
Ensure proper connections or
replace the w ires.
NO
C heck the reactor.
YES
YES
Replace the outdoor
electronic control box.
NO

Table of Contents