EasyManua.ls Logo

York YZB018 THRU 060 - COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

York YZB018 THRU 060
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
271457-YTG-B-0908
Johnson Controls Unitary Products 5
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
YZB01811
450
750
14,17 FC/MC/PC/UC18 600 18.0 13.2 13.00 11.00
14 HC18 600 18.0 13.2 13.00 11.00
- HD24 600 18.0 13.2 13.00 11.00
YZB02411
600
1000
14,17 FC/MC/PC/UC24 800 22.8 16.7 13.00 11.00
14,17 FC/MC/PC/UC30 800 22.8 16.7 13.00 11.00
14 HC30 800 22.8 16.7 13.00 11.00
- HD24 800 22.4 17.8 13.00 11.00
YZB03011
800
1200
14,17,21 FC/MC/PC/UC36 1000 29.2 21.3 13.00 11.00
17 HC36 1000 29.6 21.0 13.00 11.00
- HD36 1000 29.6 21.6 13.00 11.00
YZB03611
1000
1400
14,17,21 FC/MC/PC/UC36 1200 34.4 25.7 13.00 11.00
17 HC36 1200 35.2 25.7 13.00 11.00
- HD36 1200 34.8 26.1 13.00 11.00
YZB04211
1200
1600
21,24 FC/MC/PC/UC48 1400 41.0 31.8 13.00 11.00
21 HC42 1400 40.0 30.7 13.00 11.00
- HD48 1400 40.0 31.2 13.00 11.00
YZB04811
1400
1800
21,24 FC/MC/PC/UC60 1600 46.0 34.3 13.00 11.00
24 HC60 1600 46.0 33.5 13.00 11.00
- HD60 1600 46.0 33.2 13.00 11.00
24 MC61 1600 46.5 34.9 13.00 11.00
YZB06012 1600 - 2000 24 FC/MC62D 1800 54.0 40.0 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.