51
FZ221 Road Mains
Cooling capacity T amb. 30 °C T box 0 °C 2879 W 2023 W
T amb. 30 °C T box –20 °C 1692 W 842 W
Road compressor 146 cm3 displacement
Condenser fan helicoidal type 12 Vcc o 24 Vcc direct supply
air volume 2000 m3/h
evaporator fan helicoidal type 12 Vcc o 24 Vcc direct supply
air volume 1150 m3/h
mains compressor 87 cm3 displacement
mains electric motore 230V / 1~ /50Hz 6,1 A 2 HP 1,5 Kw
(road oper.) 400V / 3N~ /50Hz 3,5 A 2 HP 1,5 Kw
FZ228 Road Main
Road cooling capacity T amb. 30 °C T box 0 °C 3174 W 2352W
T amb. 30 °C T box –20 °C 1793 W 1169W
Road compressor 146 cm³
Condenser fan helicoidal type 12 Vdc direct supply
Air volume 2000 m³/h
Evaporator fan helicoidal type 12 Vdc direct supply
Air volume 1150 m³/h
Main compressor 87 cm³
Electric motor (mains) supply 230/1 ~ /50Hz o 400/3N ~/50 Hz
FZ229 Road Main
Road cooling capacity T amb. 30 °C T box 0 °C 3732W 2570W
T amb. 30 °C T box –20 °C 2085W 1171W
Road compressor 145 cm³
Condenser fan helicoidal type 12 Vdc direct supply
Air volume 1350 m³/h
Evaporator fan helicoidal type 12 Vdc direct supply
Air volume 1350 m³/h
Main compressor 92 cm³
Electric motor (mains) supply 230/1 ~ /50Hz o 400/3N ~/50 Hz
4. Fitting compressor mechanical Kit on the road
See instructions for use supplied with Kit
This fitting must be carried out first.
Road compressor
In order to carry out installation correctly, check the components, see list of accessories.
Then proceed, following the instructions below.
Components
- Condenser (complete with electric control box)
- Evaporator
- Control box
LIST OF ACCESSORIES:
• Installation Kit FZ213-214-218-221 Cod.1KNS002
• Installation Kit FZ219 Cod. 1KNS003
• Installation Kit FZ228-229 Cod.1KNS004
• Electrical mains connection Kit 213/214/218/219/228T/229 Cod.1KCR003
• Electrical mains connection Kit 214/218/219/228M/229 Cod.1KCR004
• Electrical mains connection Kit 213 Cod.1KCR014
• Electrical road connection Kit 213/218/219/228/229 Cod.1KCS002
• Oil separator Kit FZ Cod. 1KSP001
• Refrigerator connection Kit