Page 18
5.2 DESCRIPTION OF PROGRAMMABLE FUNCTIONS (OPTIONS)
Using the CONFIG MENU of the console, it is possible to select from the following
options:
SUBMENU “SET OPTIONS”:
1 HOUR COUNTER:
- RUNNING: The counter registers travel time only.
- KEY ON: The counter registers when the key switch is Closed.
2 QUICK INVERSION:
- BELLY: Quick inversion is activated while the Belly Button is
pressed.
- TIMED: Quick inversion is activated, while the Belly Button is
pressed, maximum for 3 second.
3 AUX OUTPUT #1:
-ABSENT: A11 output is not used: the controller carry out monitor
function as described at the paragraph 2.5.
-PRESENT: A11 output drives an electromechanical brake. The
controller does not carry out monitor function, but locks
the brake while in rest or alarm status.
4 BATTERY CHECK:
-ON: alarm indication, speed reduction and current reduction
when battery charge =<20%.
-OFF: no alarm indication, no speed and current reduction with
battery discharged.
5 SET ACCEL TYPE:
-OPTION #1: standard 0÷5V potentiometer input.
-OPTION #2: 5÷0V potentiometer input.
6 BACKING FUNCTION:
-ON: input A9 is used as enable backing input.
-OFF: input A9 is a speed reduction; no backing function
available.
7 HANDLE SWITCH:
-PRESENT: A4 is a tiller input: incorrect start if it's closed at key on;
no delay if it is switched off.
-SEAT: A4 is a seat input: no incorrect start if it's closed at key
on; programmable delay if it is switched off.