14 FIELD NOM. CURR. = Nominal Field Current. This parameter fixes the minimum
Field Current when the potentiometer is between 0% and 60% without total
conduction of the Armature. Adjustment should be made with reference to the Data
on the Motor Label. (The indication of Nominal Field Current).
15 CREEP SPEED = Minimum Speed. This Parameter sets the minimum voltage
applied to the motor at the start of travel.
16 FIELD CURR MAX = Maximum field current. The chopper reaches this field current
when the armature current is at the maximum value.
17 BACKING TIME = Maximum backing function time.
18 BACKING SPEED = Fixed speed when the backing function is active.
19 SEAT MICRO DELAY = This parameter sets the time for which the seat switch
opening is ignored.