Questions and Answers

  • L
    Lisa DelgadoAug 18, 2025
    What to do if my Zephyr Ventilation Hood doesn't work after installation?
    • D
      Darren MorrisonAug 19, 2025
      If your Zephyr Ventilation Hood doesn't work after installation, check the following: Ensure the power source is turned ON by verifying the circuit breaker and unit's power are ON. Check that the power line and cable locking connector are properly connected to the unit. Make sure the wirings at the switch board and control board are connected correctly. If the switch board or control board is defective, it should be replaced.
  • E
    Ethan HayesAug 21, 2025
    Why does my Zephyr Hurricane AK2500CS turn on by itself?
    • Z
      zbairdAug 21, 2025
      If your Zephyr Ventilation Hood turns on by itself, it might be because a spotlight or kitchen lamp is shining directly onto the switch controls. The switch controls are light sensitive, and a direct light source can disrupt their function.
  • K
    Kenneth NewtonAug 23, 2025
    What to do if my Zephyr Hurricane AK2500CS turns on by itself?
    • T
      tmillerAug 23, 2025
      If your Zephyr Ventilation Hood turns on by itself, it might be because a spotlight or kitchen lamp is shining directly onto the switch controls. These controls are light sensitive, and a direct light source may disrupt their function.
  • S
    Samuel KaneAug 26, 2025
    What to do if Zephyr Hurricane AK2500CS light works, but the blower isn't turning?
    • G
      griffinheatherAug 26, 2025
      If the light works but the blower isn't turning on your Zephyr Ventilation Hood, there could be several reasons: * The blower cable might be disconnected, so check and connect it. * There might be debris or an obstruction in the motor, which you should remove. * The motor could be defective or seized, requiring you to change the blower. * A damaged capacitor could also be the cause, so replace the capacitor. * Lastly, the switch board or control board might be defective, requiring you to change the defective part.
  • H
    hheathAug 28, 2025
    How to fix lights if the blower is working on Zephyr Ventilation Hood?
    • K
      Kimberly DavisAug 28, 2025
      If the blower is working, but the lights are not on your Zephyr Ventilation Hood, check these potential issues. First, the LED light connector might be disconnected; ensure it is properly connected. Second, the LED light itself could be defective and need replacement. Finally, the switch board or control board might be defective, and you would need to change it.
  • J
    Jillian McculloughAug 30, 2025
    What to do if my Zephyr Hurricane AK2500CS Ventilation Hood light works but the blower isn't turning?
    • M
      Michael DunnAug 30, 2025
      If the light works, but the blower isn't turning on your Zephyr Ventilation Hood, several issues could be the reason. Start by checking the blower cable to ensure it's properly connected. Also, inspect the motor for any debris or obstructions that may be preventing it from turning. If those aren't the problem, the motor may be defective or seized, the capacitor might be damaged, or the switch board or control board could be defective, requiring you to change the defective part.
  • M
    marie43Sep 1, 2025
    What to do if my Zephyr Hurricane AK2500CS is vibrating?
    • V
      Virginia Juarez MDSep 1, 2025
      If your Zephyr Ventilation Hood is vibrating, it could be due to several reasons. First, check if the blower is securely in place and tighten it if necessary. A damaged blower wheel can also cause vibration, so consider replacing it. Lastly, ensure the hood itself is properly secured; check the installation.
  • D
    David MorganSep 4, 2025
    What to do if my Zephyr Hurricane AK2500CS Ventilation Hood doesn’t work after installation?
    • J
      jleeSep 4, 2025
      If your Zephyr Ventilation Hood doesn’t work after installation, first ensure that the power source is turned ON by checking the circuit breaker and the unit's power. Then, verify that the power line and cable locking connector are properly connected. Also, check the wirings at the switch board and control board to ensure they are connected correctly. If the problem persists, the switch board or control board may be defective and need to be replaced.
  • E
    Emily ButlerSep 6, 2025
    Why is my Zephyr Hurricane AK2500CS not venting properly?
    • D
      davidknappSep 6, 2025
      There are several reasons why your Zephyr Ventilation Hood might not be venting properly. It could be due to using the wrong type of ducting; flexible ducting can reduce airflow by up to 50%, so change to solid rigid metal ducting. The hood might be hanging too high from the cooktop; adjust the distance to be within 24” and 32”. Also, wind from opened windows or doors can affect ventilation, so close them. Finally, there might be a blockage in the duct opening or ductwork; remove any obstructions.
  • R
    Robert GloverSep 8, 2025
    Why is my Zephyr Hurricane AK2500CS vibrating?
    • C
      Carrie ParrishSep 8, 2025
      If your Zephyr Ventilation Hood is vibrating, it could be due to a few reasons. The blower might not be secured in place, so tighten it. A damaged blower wheel could also cause vibration, requiring you to replace the blower. Lastly, the hood itself might not be secured properly, so check the installation.

Summary

Safety Information

Critical Safety Warnings

Covers fire, electrical, ducting, and health hazards.

Installation Instructions

Mounting Height, Clearance, & Ducting

Recommended dimensions for hood installation above the range.

AK21 Hood Specifications

Detailed dimensions and specifications for the AK21 model.

AK25 Hood Specifications

Detailed dimensions and specifications for the AK25 model.

AK65 Hood Specifications

Detailed dimensions and specifications for the AK65 model.

Features & Controls

AK21 Capacitive Touch Controls

Explanation of controls for the AK21 model with capacitive touch.

AK25 Electronic Touch Controls

Explanation of controls for the AK25 model with electronic touch.

Maintenance

ACT Conversion

Wiring Diagram

Troubleshooting

Limited Warranty

Zephyr Hurricane AK2500CS Specifications

General IconGeneral
Colorstainless steel
Hood Typeunder cabinet
Venting Typeducted, external
Temperature Sensorno
Number of Fan Speeds3
CFM695 cubic feet per minute
Sones5.5 sones
Control Typebutton
Delay Startyes
Interior Lightyes
Remote Controlno
Voltage120 volts
Weight and Dimensions IconWeight and Dimensions
Depth20 1/8 inches
Height7 inches
Width29 3/4 inches
Net Weight30 pounds