USE, CARE AND INSTALLATION GUIDE
Read all instructions before installing and operating this appliance
IMPORTANT SAFETY NO TICE
Installation
The installation instruction in this manual is intended for qualified installers, service
technicians or persons with similar qualified background. DO NOT attempt to install this
appliance yourself. Injury could result from installing the unit due to lack of appropriate
electrical and technical background.
All electrical wiring should be properly installed, insulated, and grounded. Overly
accumulated grease on old duct work should be cleaned out or duct work should be
replaced if necessary to avoid the possibility of grease fire. Check all sections and joints
on duct work to insure proper connection and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these
instructions for future reference.
ALWAYS leave safety grills attached in place at all times. Operating blowers could catch
on to hair, fingers, and loose clothing.
Keep unit and residue containers clean from grease accumulation from time to time.
NEVER dispose foreign substances into the blowers. Do not dispose cigarette ashes or
ignitable substances into the blowers.
Cleaning
Use with extreme caution while performing the Self Cleaning Function and safety grills
are removed. Beware of fingers, hair, loose clothing from getting in the blowers and
NEVER leave children unattended.
NEVER disassemble parts to clean without proper instructions. Disassembly are
recommended to be performed by qualified personnel only. We are not responsible for
injury due to negligence and the warranty of the unit automatically expires due to
improper maintenance. Call our Service Center for removal instructions.
WARNING
MODEL: TYPHOON AK2100, AK2136

Questions and Answers

  • E
    Eric FoxAug 17, 2025
    How to clean safety grill of Zephyr Typhoon AK2100?
    • T
      Tonya HendersonAug 17, 2025
      The self-clean feature on your Zephyr Ventilation Hood only cleans the internal housing. Remove the safety grill to clean it in the dishwasher and clean all surfaces periodically as instructed.
  • A
    Amanda SmithAug 19, 2025
    Why does cooking smoke dissipate before reaching the Zephyr Typhoon AK2100?
    • J
      jhaneyAug 19, 2025
      If cooking fumes and smoke dissipate before reaching the Zephyr Ventilation Hood blower, there are several potential causes. Ensure you are using a damper-type sidewall cap. Reduce the number of elbows and the length of ductwork, or increase the duct size. Verify that all joints are properly connected, sealed, and taped. Confirm that the unit is installed at the recommended height and covers the entire cooking area. Also, ensure that doors and windows are closed to avoid airflow disruption and that blowers are set to high speed during heavy cooking.
  • D
    Dr. Penny OlsonAug 22, 2025
    Why is my Zephyr Typhoon AK2100 Ventilation Hood so noisy?
    • T
      Traci GomezAug 22, 2025
      Zephyr Ventilation Hood blowers are designed to perform up to 850 cfm. A properly functioning motor should be relatively quiet. However, the suction can generate noise levels up to 6 sones when both blowers are on maximum speed. Use maximum speed only when necessary, such as during heavy pan-frying or wok cooking. Lower speeds are sufficient for moderate cooking like steaming or broiling.
  • L
    Laurie ScottAug 25, 2025
    Why does my Zephyr Typhoon AK2100 vibrate when the blowers are on?
    • K
      Kimberly PearsonAug 26, 2025
      Vibration in your Zephyr Ventilation Hood when the blowers are on may be due to improper securing of the unit to the cabinet, or the cabinet itself might need to be further secured to the wall studs.
  • P
    Patrick ReyesAug 27, 2025
    What to do if my Zephyr Ventilation Hood doesn't work after installation?
    • L
      Lisa HorneAug 27, 2025
      If your Zephyr Ventilation Hood isn't working after installation, check that the unit is plugged in, power is turned on, and all electrical wiring is properly connected.
  • P
    pjenkinsAug 30, 2025
    Why does my Zephyr Ventilation Hood blower seem weak?
    • P
      Pamela GarciaAug 30, 2025
      Weak blowers in your Zephyr Ventilation Hood may be due to clogged tubes connected to the internal housing or the hood not being level. Try unclogging the tubes or reinstalling the hood.
  • M
    Michael BrewerSep 2, 2025
    What to do if something is spinning inside my Zephyr Typhoon AK2100 Ventilation Hood?
    • M
      mikeyoungSep 2, 2025
      If something seems loose and is spinning inside your Zephyr Ventilation Hood when the blowers are on, there might be foreign particles in the discharge opening or debris from old ductwork. Disconnect the ductwork to inspect and remove any foreign particles.
  • A
    alexander77Sep 4, 2025
    How to fix the light on my Zephyr Typhoon AK2100?
    • S
      Steven RamirezSep 5, 2025
      If the light in your Zephyr Ventilation Hood isn't working, the bulb may need replacement. The bulb could have been damaged during shipping, so try replacing it.
  • J
    john70Sep 7, 2025
    What to do if Zephyr Typhoon AK2100 light is on but blowers aren't turning?
    • W
      washingtondavidSep 7, 2025
      If the light is on but the blowers are not turning, or seem to be scraping, the blower blade unit of your Zephyr Ventilation Hood might be mounted too low and scraping. Loosen the hex screw on the blade unit and adjust it to the proper height.
  • M
    Michael LivingstonSep 12, 2025
    Why is no grease collected in the clean cups of my Zephyr Typhoon AK2100?
    • A
      Anne DyerSep 12, 2025
      Grease flow varies depending on the amount, methods, and types of cooking. If you frequently pan-fry and steam, the vapor from the steam will liquefy accumulated grease in the internal housing, causing it to flow into the clean cups of your Zephyr Ventilation Hood.

Summary

CONTROLS

Control Panel Overview

Introduces the touch control module and its main functions.

Blower Speed and Operation

Details on turning blowers on/off and adjusting speed levels 1-6.

Light Controls and Indicator Functions

How to operate lights, dimming, and understanding speed/delay indicators.

Timed Delay Off Feature

Setting the hood to automatically shut off after 5, 10, or 15 minutes.

INSTALLATION

Clearance and Ducting Requirements

Specifies minimum clearances and requirements for duct size, type, and installation.

Duct Opening and Electrical Setup

Details dimensions for duct openings and electrical/drill locations for models.

Mounting and Securing the Hood

Step-by-step guide for template use, marking, anchoring, and mounting the hood.

Convertible Discharge Options

Instructions for converting the hood for vertical or rear discharge configurations.

CLEANING & MAINTENANCE

Self-Clean Feature Explanation

Describes the automatic self-cleaning function for liquefying cooking residue.

Safety Grill and Self-Clean Operation

Instructions for cleaning safety grills and performing the self-clean cycle.

Cleaning Tips and Light Bulb Replacement

Tips for residue container cleaning and instructions for replacing halogen light bulbs.

Surface Maintenance

Guidance on cleaning and polishing the appliance's exterior surfaces.

TROUBLE SHOOTING

Common Operational Issues and Solutions

Addresses issues like unit not working, blower scraping, loose parts, and noise.

Light, Grease, and Safety Grill Troubleshooting

Solutions for light not working, no grease collection, and dirty safety grills.

Blower Performance and Airflow Issues

Troubleshooting weak blower performance and cooking fumes dissipation issues.