EasyManuals Logo

Zephyr Typhoon AK2100BS User Manual

Zephyr Typhoon AK2100BS
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly
grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire with ground. Please also refer to Electrical Diagram on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements, purchase and install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zephyr Typhoon AK2100BS and is the answer not in the manual?

Zephyr Typhoon AK2100BS Specifications

General IconGeneral
BrandZephyr
ModelTyphoon AK2100BS
CategoryVentilation Hood
LanguageEnglish

Related product manuals