6
3.
Installation Instruction
3.1
Before Installation
•
Read all the instructions before using and installing this product.
•
Do not use this product if power cable or charging cable have any damage.
•
The product is without enclosure for ingress protection, please keep the product
under clean and adaptive circumstance after un-packed.
•
The product should be installed only by licensed contractor, and/or licensed
technician in accordance with all building code, electrical code and safety
standard.
•
The product should be inspected by a qualified installer prior to initial use. Under
no circumstances will compliance with the information in this manual relieve
user of his /her responsibilities to comply with all applicable code and safety
standard.
•
The product is without protective enclosure and with high voltage will cause
electric shock, not allow to close or touch the product during operation. And
must turn the power off or equip safety protective device before approach or
maintain the product.
•
Power feed must be Single Phase Wye configuration with TN(-S)/ TT grounding
systems. The capacity of power supply should be higher than 196 kVA and
current of NFB should be higher than 400A in order to have function correctly.
•
In the installation of TN(-S) system: the neutral (N) and the PE of the power
distribution are directly connected to the earth. The PE of the charger equipment
is directly connected to the PE of power distribution and separate conductor for
PE and neutral (N).
•
In the installation of TT system: the neutral (N) and the PE of the power
distribution are directly connected to the earth. The PE of the charger equipment
is isolated to the PE of power distribution to the earth.
•
The product should be installed in free air area and keep at least 90cm clearance
distance to all air vent of the product.
•
Need sufficient space for product installation and maintenance, please keep at
least 90 cm as clearance distance around the product.