INSTALLATION INSTRUCTIONS & USER MANUAL
210005 V2.00 AUG 2017 - ZIP APIII/5-15(OB)
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
ZIP
AQUAPOINT III
INSTALLATION INSTRUCTIONS & USER MANUAL
MODEL NUMBER:
AP3/05 - AP3/15, AP3/05/OB - AP3/15/OB
Direct unvented water heaters.
Question and Answer IconNeed help?

Do you have a question about the Zip AQUAPOINT III AP3/05 and is the answer not in the manual?

Overview

The document is an installation instructions and user manual for the Zip Aquapoint III, a series of direct unvented water heaters.

Function Description

The Zip Aquapoint III is an unvented water heater designed for direct connection to the incoming mains water supply. It can serve one or more outlets using conventional taps. The unit accommodates expanded hot water that occurs with each heating cycle. A manually resettable safety cut-out automatically cuts off the electrical supply to the heating element in case of a malfunction. A sacrificial magnesium anode is fitted to the vessel to provide anti-corrosion protection for both the vessel and the heating element.

Important Technical Specifications

The Zip Aquapoint III series includes models AP3/05 - AP3/15 and AP3/05/OB - AP3/15/OB, indicating different capacities and installation types (Overbasin/Underbasin).

General Specifications:

  • Power Rating: 2,000 W
  • Nominal Supply Voltage: 230 VAC
  • Protection Class: IP24
  • Maximum Working Pressure: 0.55 MPa (5.5 bar)
  • Water Connections: 1/2" BSP
  • Inner Vessel Material: Glass enamelled steel sheet, pressure tested to 1.2 MPa (12 bar).
  • Casing Material: Impact resistant plastic.
  • Insulation: High efficiency polyurethane foam.

Model-Specific Data:

Model Installation Declared Load Profile Energy Efficiency Class Energy Efficiency (nwh) (%) Annual Electricity Consumption (kWh) Rated Volume (l) Weight Empty / Full (kg) Heat Up Time (10°C to 65°C) (mins) Packaging Dimensions (mm)
AP3/05/OB Overbasin XXS A 35.9 514 6.2 6.5/13.5 11 300x300x440
AP3/05 Underbasin XXS A 35.2 525 6.6 6.5/13.5 11 300x300x440
AP3/10/OB Overbasin XXS A 36.3 508 9.8 8.5/18.5 20 300x400x530
AP3/10 Underbasin XXS A 35.2 524 9.9 8.5/18.5 20 300x400x530
AP3/15/OB Overbasin XXS A 36.1 510 14.8 9.8/24.7 29 350x400x540
AP3/15 Underbasin XXS A 35.3 523 14.9 9.8/24.7 29 350x400x540

Dimensions (mm):

Model A B C D E F
AP3/05(0B) 376 256 260 100 252 140
AP3/10 (0B) 480 350 265 100 378 140
AP3/15 (0B) 480 350 310 100 378 140

Usage Features

  • Installation: Must be installed vertically. Hot supply (red) is on the left, cold supply (blue) on the right when facing the heater. Overbasin models have connections underneath, undersink models have connections at the top. Undersink and oversink models are not interchangeable.
  • Temperature Control: A temperature control knob allows adjustment from 9°C to 75°C. The economy 'e' setting maintains approximately 41°C for AP3/05/0B, AP3/05 models, and 35°C for AP3/10/0B, AP3/10, AP3/15/0B, AP3/15 models, minimizing limescale formation and heat loss. The maximum stored water temperature can be limited by adjusting a knob limiter inside the unit.
  • Frost Protection: The temperature control knob can be set to '*' to maintain a stored water temperature of approximately 9°C, protecting the heater from freezing (does not extend to pipework).
  • Safety Features: Includes a manually resettable safety cut-out for over-temperature situations. The appliance must be earthed and connected to the supply through an isolating switch with contact separation of at least 3mm in all poles, protected by a suitably rated RCD and MCB/cartridge fuse.
  • Water Expansion Management: Regulations permit expanded hot water to be accommodated within the supply pipework if no check valve or stop valve prevents reverse flow. For static water supply pressures under 3.5 bar, accessory pack AQ2 (expansion vessel and check valve) is recommended. For pressures exceeding 3.5 bar, accessory pack AQ2 and AQ3 (pressure reducing valve and line strainer) are recommended. A 6 bar expansion relief valve must be fitted on the cold water supply. An optional temperature and pressure relief valve (AQ1) can be used.
  • Pre-wiring: The unit comes pre-wired with a 3-core cable for connection to a 230V AC mains supply via a double pole fused spur (minimum 13 amps).

Maintenance Features

  • Regular Inspections: Key components should be inspected at no greater than 12-month intervals by a competent person (electrician or plumber) familiar with unvented systems.
  • Sacrificial Anode Check: The condition of the magnesium anode should be checked regularly to ensure its effectiveness in protecting the vessel and element from corrosion. This can be done visually by removing the element assembly or electrically by checking the current between the anode and vessel (should exceed 0.4mA). If badly corroded or if the current is insufficient, the anode should be replaced.
  • Valve Operation Checks: Expansion relief valve and T&P relief valve (if fitted) should be checked for correct operation.
  • Expansion Vessel Check: If an expansion vessel is fitted, its pressure should be checked according to the label on the side of the vessel.
  • Line Strainer Cleaning: If a pressure reducing valve is fitted, the integral line strainer should be inspected and cleaned as necessary.
  • Discharge Pipe Check: Ensure the discharge pipe is free of obstructions.
  • Electrical Connections: All electrical connections should be checked for tightness.
  • Limescale Prevention: To minimize limescale formation, the unit should always be operated at the lowest convenient temperature, as damage or failures caused by limescale are excluded from the warranty.
  • Troubleshooting: The manual provides a fault-finding guide for common issues such as over-temperature cut-out, intermittent or continuous water discharge from the tundish, no hot water flow, and cold hot water.
  • Safety Precautions: Always disconnect the appliance from the mains power supply before carrying out any work. Do not use the water heater if suspected of being frozen. Isolate power and water supply immediately in case of malfunction, leaks, or seepage, and contact a competent person for repairs. Do not block or restrict safety valve discharge or tamper with safety valves.

Zip AQUAPOINT III AP3/05 Specifications

General IconGeneral
BrandZip
ModelAQUAPOINT III AP3/05
CategoryWater Heater
LanguageEnglish