801314 - Zip HydroTap BC, BCHA, AIO, Installation Instructions - Aug 2015 - V2.01 Page 37 of 40
1.
With the unit in Normal operating mode and with the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral position.
7.
To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration.
This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
Safety
sensor
Pull both levers forward
Safety Sensor Calibration
End of Life Disposal
In order to help preserve our environment we ask that you dispose of this product correctly. Please contact
your local city council for collection centre details.