13
Location of Water System
BEFORE INSTALLATION
LOCATION OF THE WATER SYSTEM
The water connected to the refrigeration unit must be potable.
The location of the water system must be within the range provided below.
The unit's water system must be connected to the main water system in the house. The user
must be able to switch the water system on/off with a valve when necessary.
Objects that may pierce the water hoses or cause them to twist must not be present where
the water line is installed.
Pressure of the water system must be between 25-80 psi (1.7-5.5 Bars).
If the water pressure exceeds 80 psi (5.5 Bars), install a pressure-limiting device or water
pressure protector to the inlet valve. Never install or operate the appliance if it's possible for
the water pressure to exceed 120 psi (8.3 Bars).
Make sure there is no leakage when making water connections. Otherwise,
there will be water on the floor and the cabinets may get damaged.
You will need a hose with a minimum length of 60" (1524 mm) and a diameter
of 1/4" (6 mm) for water connections of the product during installation.
A connector that has a thread with an external diameter of 1/4" (6 mm)
must be used to connect the hose end to the product.
Before completing installation, make sure water flows and there is no
leakage. Damage may occur if leaks are present.
WARNING