13
Location of Water System
BEFORE INSTALLATION
LOCATION OF THE WATER SYSTEM
• The water connected to the refrigeration unit must be potable.
• The location of the water system must be within the range provided below.
• The unit's water system must be connected to the main water system in the house. The user
must be able to switch the water system on/off with a valve when necessary.
• Objects that may pierce the water hoses or cause them to twist must not be present where
the water line is installed.
• Pressure of the water system must be between 25-80 psi (1.7-5.5 Bars).
• If the water pressure exceeds 80 psi (5.5 Bars), install a pressure-limiting device or water
pressure protector to the inlet valve. Never install or operate the appliance if it's possible for
the water pressure to exceed 120 psi (8.3 Bars).
• Make sure there is no leakage when making water connections. Otherwise,
there will be water on the floor and the cabinets may get damaged.
• You will need a hose with a minimum length of 60" (1524 mm) and a diameter
of 1/4" (6 mm) for water connections of the product during installation.
• A connector that has a thread with an external diameter of 1/4" (6 mm)
must be used to connect the hose end to the product.
• Before completing installation, make sure water flows and there is no
leakage. Damage may occur if leaks are present.
WARNING