Redox regulati on
Translation of the original instructi ons in french

Questions and Answers

  • A
    adavenportAug 18, 2025
    Why is the free chlorine level too low in my Zodiac Lighting Equipment (murky water)?
    • P
      Paul GarciaAug 18, 2025
      The free chlorine level might be too low due to several reasons. The water balance could be incorrect (high pH, etc.), or the Redox set point might be too low. Also, the daily filtering time may be too short. To resolve this: * Check and correct the water balance parameters. * Use the «Boost» mode. * Ensure the set point is above 650mV. * Ensure the daily filtering time is at least 12 hours per day during the season.
  • M
    Michael FergusonAug 20, 2025
    What to do if my Zodiac Chlor Expert Lighting Equipment shows an unsuitable or constantly unstable value?
    • P
      Philip LewisAug 20, 2025
      If your appliance shows an unsuitable or constantly unstable value, it could be due to a damaged Redox sensor connection cable, a worn Redox sensor, or the Redox sensor cable being too close to an electric cable. Here’s what you can do: * Check the cable and/or the BNC connector. * Reduce the distance between the appliance and the sensor. * Replace the Redox sensor. * Place the sensor in a more suitable location.
  • K
    Krista BenderAug 22, 2025
    What to do if my Zodiac Lighting Equipment indicates «OFA Alarm»?
    • J
      Justin AlvaradoAug 23, 2025
      If the «OFA Alarm» is activated, it means the first step in the over feed safety system has been triggered because the time exceeds 75%. To resolve this: * Press to stop the alarm. * Check the sensor and/or the pool chlorine level.
  • M
    Mr. Oscar Cruz Jr.Aug 26, 2025
    What to do if my Zodiac Chlor Expert Lighting Equipment indicates «OFA Stop»?
    • A
      April PattersonAug 26, 2025
      If the «OFA Stop» is activated, it signifies the second step in the over feed safety system has been triggered because the time is at 100%. Here’s how to address it: * Press to stop the alarm. * Check the sensor and/or the pool chlorine level.
  • D
    debbiefosterAug 27, 2025
    Why is the free chlorine level too high in my Zodiac Chlor Expert Lighting Equipment?
    • R
      Richard ToddAug 28, 2025
      A high free chlorine level can be caused by an incorrect water balance (low pH, etc.) or a Redox set point that is too high. You should: * Check and correct the water balance parameters. * Ensure the set point is not too high. * Power off the appliance.
  • B
    Benjamin JacksonAug 29, 2025
    What to do if my Zodiac Chlor Expert Lighting Equipment shows a value close to 0mV?
    • K
      Kayla LoweAug 29, 2025
      If the appliance consistently displays a value near 0mV, it may indicate a cable problem or a BNC connector issue. Check that the connection between the sensor and the control box is not short circuited (between the cable’s central core and the external shielding). Also, check for humidity and/or condensation at the BNC connector level.
  • R
    Rachel SchaeferSep 1, 2025
    What to do if I get a calibration impossible error message or Redox sensor reliability is less than 25% on my Zodiac Chlor Expert Lighting Equipment?
    • J
      Jessica PetersenSep 1, 2025
      If you receive an error message during calibration or the Redox sensor reliability is below 25%, it could be due to a defective buffer solution, a dirty or defective sensor, or a worn sensor. Try the following: * Check that the solution used is 465mV. * Use new buffer solution. * Begin calibration again. * Check the condition of the sensor tip and the porosity of the sensor. * Clean the sensor by leaving its extremity in a 10% solution of hydrochloric acid. * Replace the sensor.
  • R
    rogerrojasSep 3, 2025
    What to do if my Zodiac Chlor Expert indicates «Error»?
    • S
      stephaniegallegosSep 3, 2025
      If the appliance displays an «Error», it could be due to used buffer solution(s), a dirty Redox sensor, or a defect with the Redox sensor. Here's what to do: * Replace the buffer solution(s). * Clean the Redox sensor using a 10% HCl solution. * Replace the Redox sensor.
  • J
    Julie RobinsonSep 6, 2025
    What to do if my Zodiac Lighting Equipment indicates «Flow»?
    • J
      Julie JohnsonSep 6, 2025
      If the appliance displays «Flow», it could be due to the filtering being stopped or an incorrect connection. To resolve this: * Start and/or check the filtering. * Check the electric connections.
  • M
    marisasmithSep 8, 2025
    What does «OFA Check» mean on my Zodiac Chlor Expert Lighting Equipment, and what should I do?
    • R
      robert75Sep 8, 2025
      If «OFA Check» is indicated, it signifies a Redox sensor measurement test is in progress because the «OFA Stop» was activated during a previous filtering cycle. Wait for the end of the procedure (1 hour) then check the sensor and/or the pool chlorine level.

Summary

Warnings

General Warnings

Important safety precautions for appliance use and maintenance.

Warnings Associated with Electrical Appliances

Specific safety guidelines related to electrical connections and operation.

Installation

Hydraulic Connections

Guidelines for sensor and injection point placement.

Sensor and Injection Point Installation

Step-by-step process for installing the ORP sensor and injection points.

Electrical Connections

Instructions for connecting the appliance to the power supply.

Use

Calibrating the Sensor

Procedure for regularly calibrating the ORP sensor for accuracy.

Troubleshooting