Press 'C', 'A', and 'B' buttons simultaneously to view the first four sets of two digits for firmware revision.
Turn off all power and follow electrical codes to prevent shock hazards before installation.
Turn off power, open power center, and disconnect the tri-sensor cable from the board.
Connect the tri-sensor cable to the adapter, then the adapter to the power interface board.
Turn on power to AquaPure/PureLink systems and circulation pump after installation.
Turn off power and follow electrical codes to avoid shock hazards before installing on AKC13 front board.
Turn off power, open power center, and disconnect the tri-sensor cable from the AKC13 front board.
PureLink systems with AKC13 front board require additional cable assembly R0538600 for installation.
Connect cable assembly R0538600 and tri-sensor cable to the AKC13 front board.
Install adapter, restore power, wait 4 minutes, then press and hold calibration button for 5 seconds.
The 'Flow' indicator illuminates when the tri-sensor adapter is properly calibrated.
Lists Tri-Sensor Adapter and Installation Kit Instructions with quantities for reference and reordering.